6.0 Maintenance 

 

6.2   Short Term Storage/Fresh Water Flush   

 

 

Ideally, the SEA STAR performs optimally when the RO unit is used periodically. However, the 
Likelihood of bacterial and biological growth in the membranes increases, when stagnant seawater (in 
extended periods) is in contact with the membranes. A freshwater flush procedure is necessary to 
prevent clogging and growth of organic contaminants in the RO system and its membranes. This 
method pushes out older stagnant seawater (saltwater) out of the membranes and replacing it with 
freshwater (non-saltwater), leaving less chance of fouling the membranes. The freshwater flush 
procedure should be used when 

the unit will be placed idle or in “stand by” condition for more than 

seven days 

OR 

idle for three days in hot, tropical climates. We recommend a fresh water flush after 

every use. Although they do not attack the membranes or other system components directly, high 
concentrations of biological matter can block enough of the product water channels to cause a 
reduction of as much as 40% of the total system capacity. 

PERFORM A FRESHWATER FLUSH TO THE RO UNIT WITH NON-CHLORINATED FRESH 
WATER ONLY. EXPOSING THE MEMBRANES TO CHLORINATED WATER WILL CAUSE 
IRREVERSIBLE DAMAGE AND VOID THE RO UNIT WARRANTY. THE FRESHWATER FLUSH 
SYSTEM USES A

 

CARBON FILTER INLINE BEFORE SYSTEM TO CONSUME THE CHLORINE. 

 

 

 

 

 

 

 

 

 

 

 

       

 

 

Turn the handle at the strainer to Fresh Water Position  (Selector Valve) 

 

Start the unit. 

 

Let the system run for app. 10 minutes. At least so long, until the high pressure has 
dropped.  

 

Stop the system. 

 

Place the selector Valve back to Sea Water.  

 

For storage longer than one week, replace the 5µ pre-filter. An old filter can contaminate 

the system.   

 

Now you can leave the System in Stand-by for 3-4 Months. In very hot climates only on month. 

 

Note: A fresh water flush after using the system will increase the lifetime of the membrane. However, you should not 
have sea water in the system for more than 2 days. 

               

 

 

 
 

 

 
 

 

  

 

 

 

 

 

 
 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

      13 

Summary of Contents for Whisper 30

Page 1: ...12 24 Volt DC 230 V AC User Guide and Installation handbook PureWater H Fehlemann Entsalzungsanlagen Bodelschwinghstrasse 37 33142 B ren Germany www watermaker de purewater watermaker de Whisper 30 in...

Page 2: ...ions to PH Stabilizer Only COMPACT Models 9 4 4 1 Electric Control Box Option 10 5 0 How to use the System 11 Preservation Configuration Flow Diagram 12 6 0 Maintenance 13 6 2 Short Term Storage Fresh...

Page 3: ...Handbook The Sea Star Whisper 30 modular Frame individual parts ETD Basic unit Filter system Whisper Vane Pump Pre Filter Vane Pump 230V The dimensions of Motor and pump are subject to change because...

Page 4: ...e in H fen oder in Gebieten wo Kraftstoff und l im Seewasser ist Don t use the unit in ports and areas where the seawater is contaminated with fuel and oil 5 Wenn Sie die Anlage in Frisch oder Brackwa...

Page 5: ...the concentrated solution is increased to above the osmotic pressure fluid flow will be reversed This condition called Reverse Osmosis can be established by artificially pressurizing the more concentr...

Page 6: ...er A system such as this is said to have a salt passage of 1 2 0 Whisper 30 integral 2 1 The general scope of application for the WHISPER integral systems You can use the WHISPER systems without restr...

Page 7: ...is a 50 washable filter and reduces the particles to protect the vane pump Pre Filter The Pre Filter is a 5 changeable filter cartridge and protects the Membrane from fine particles Note The pre filte...

Page 8: ...uct water The diversion Valve is located at the right side of the Main control panel There is an emergency gray button to override the valve Only to be used when the controller is not working Push and...

Page 9: ...ar Low Pressure 7 12 Bar Maximum Salinity 46000 ppm ppm Parts per million Temperature Range 1 C to 45 C PH Range 2 11 The produced fresh water is better than WHO requirement 4 0 Installation 4 1 Requi...

Page 10: ...from the Carbon Filter FWF System or if installed from the Selector Valve 1 if a Clean Rinse Kit is installed Vane Pump Feed Pump The outlet of the Strainer has to be connected to the inlet of the va...

Page 11: ...Carbon Filter FWF System The inlet of the Carbon Filter must be connected with your boat pressure water Step 2 Connect the outlet of the Feed Pump with the inlet of the red Pre Filter Step 3 Connect t...

Page 12: ...ways from the top of Tank 4 4 Hose Connections to PH Stabilizer Only COMPACT Models Step 1 The Pre Filter installation is completed Step 2 The Product Water outlet at the Manifold has to be connected...

Page 13: ...ection of the motor will result in wrong direction turning and the pump rotation is wrong Then connect the Feed Pump Cable to its respective side Step 6 Now look for 2 black cables coming out of the b...

Page 14: ...el should read between 8 to 10 Bar and the high pressure Gauge at the ETD should read in normal seawater 45 55 Bar If you test the unit in brackish water the pressure is lower Step 5 ONLY FOR COMPACT...

Page 15: ...Whisper 30 integral Handbook Preservation Configuration 12...

Page 16: ...attack the membranes or other system components directly high concentrations of biological matter can block enough of the product water channels to cause a reduction of as much as 40 of the total syst...

Page 17: ...guide the hose to the Cleaning Storage Tank This can be a simple bucket Step 3 Place the Selector Valve 1 to the right There should be a hose to the cleaning storage Tank Bucket Place the Selector Va...

Page 18: ...pping Disconnect the product water hose connection Unscrew both End caps by using a special Tool This Tool is available in special hardware shops After you have unscrewed the End Caps pull the membran...

Page 19: ...de the new Membrane from the right side into the tube Pay attention that the Membrane is exact in the middle Now you can screw the Endcaps on the tube Connect the Product Water connection To start the...

Page 20: ...Whisper 30 integral Handbuch 7 0 Flow Diagram Normal Operation 17...

Page 21: ...use the system with a 230V 50Hz Motor it is possible to switch ON and OFF with the Switch at the Panel However to use a Relay is always the better Idea Parts for this installation could be ordered via...

Page 22: ...Whisper 30 Integral Handbook 9 0 ETD Exploded Parts View 19...

Page 23: ...Whisper 30 Integral Handbook 9 1 ETD Parts 20...

Page 24: ...Whisper 30 Integral Handbook 9 1The John Guest System 21...

Reviews: