7
10.8V Li-ION
Charger
SPECIFICATION
PURE 10.8V BATTERY CHARGER
Charger Input 240V ~ 50Hz
Charger Output 10.8 V DC
Charging Time 1 hour
OPERATING INSTRUCTIONS
WARNING
This charger is designed to charge Pure
10.8V battery packs. It should only be used
for this purpose. Using this charger with any
other battery packs could be dangerous.
CHARGING A BATTERY PACK
1. Position the charger on a work bench
or similar in a well ventilated location and
ensure that the charger cannot be covered
by workshop cloths etc.
2. Plug the charger into a suitable power
socket. The green LED will illuminate.
3. Insert the Pure 10.8V battery pack into
the docking port of the charger. It will only fit
in one way round.
4. Firmly push the battery pack down into
the charger to ensure terminal connection.
The green LED will flash to confirm terminal
connection and that the charging cycle has
started.
5. When the green LED ceases flashing
but remains illuminated, the charging cycle
is completed and the battery pack is fully
charged.
6. Remove the battery pack from the charger,
and store the charger safely for future use.
CHARGING INDICATOR
This charger is designed to detect problems
that can sometimes arise with rechargeable
battery packs. The status of the two LED’s
can alert the operator to potential problems.
Please refer to the table below.
RED LED GREEN LED
CHARGER OR BATTERY PACK CONDITION
OFF
ON
Charger connected to power supply and ready to receive battery pack
OFF
FLASHING
Battery pack correctly inserted and charging cycle in progress
OFF
ON
With battery pack inserted. Battery pack fully charged
ON
OFF
Battery temperature at or above 50
0
C or below 0
0
C
ON
OFF
At least one of the three battery cells is lower than 2V
FLASHING OFF
Battery failure or battery pack not properly connected to the charger