Installation of the Electrical Wiring

 

Caution:  This procedure should only be attempted by  persons qualified to install electrical wiring. 

All wiring must comply with applicable codes and ordinances. 

1.

Locate a 120V AC, 60 Hz (alternative power sources would be used in the case of the LAF

M

 

230V units) power circuit with a junction box

 

near the air cleaner location.

2.

Check that the circuit breaker or fuse, for that circuit is rated at 15 amperes or 20 amperes.  The

 

required copper wire size will be: 

AWG #14 for 15 ampere circuits AWG #12 for 
20 ampere circuits 

3.

Caution:  Turn off the building circuit at the fuse or circuit breaker before proceeding.

4.

Locate the connection box on the air cleaner and remove the outer plate which contains the

 

knockout.  You will note the presence of three

wires on the inside of the box.  One blue, one

 

brown, and one green.

5.

Connect the blue and brown wires from the pigtails in the air cleaner, to the corresponding

 

colors in the supply circuit.  (See diagram on page

13.)

6.

Connect green wire from the grounded terminal in the air cleaner, to the grounded circuit of the

 

building wiring system.  If the building does

not have conduit it will have a green or bare ground-ing conductor for connection to the air cleaner green wire.  DO NOT CONNECT THE
GROUNDING WIRE FROM THE AIR CLEANER TO THE WHITE WIRE OF THE

 

BUILDING.  The air cleaner frame must be electrically

connected to the frame of the building or

 

the electrical conduit system.  Input electrical power should be run through flexible conduit as

recommended by the National Electrical Code or your local authority.

Reassembly of the Unit 

1.

With the unit now in place, loosen the 1/4 turn screws on the intake grille and allow the hinged

 

portion to drop down.

2.

Replace the prefilter screen, electronic cell, and carbon afterfilter, making sure to connect the

 

grid cap connector to the cell.  

REMOVE

THE PLASTIC COVER FROM THE HEPA

 

MEDIA BEFORE REINSTALLATION OF THE FILTER PAD.

3.

Close and lock the entire hinged panel into place.

Exhaust Grille Orientation 

1.

The exhaust grille side of your LAF

M

 is equipped with individually movable louvers.  To set

 

them in the air pattern which best suits your

 

needs, you simply angle them in the direction that you

 

wish to direct the airflow.

2.

A good pattern would allow for dispersion of the air so that it is not blowing straight down,

 

perpendicular to the floor. 

Start-Up and Checkout of the Unit 

To make sure the unit is operating correctly before leaving the installation, please check the following: 

1.

Check all electrical connections and make sure they are tight and properly connected.

2.

Electronic cell is in place and properly oriented so that the airflow arrow points in the direction

 

of the airflow or the HEPA Media pad is

properly oriented so that black carbon filter material is

 

facing toward the ceiling.

3.

Turn the unit on and check to see that it runs properly at all speeds.  In addition, make sure the

 

light goes on when the unit is in operation.

4.

Open the intake grille section and check to see that the unit shuts off completely.  Re-engage the

 

panel and make sure unit turns on by

watching light.
If for any reason the unit does not appear to work correctly, refer to the Troubleshooting Guide for

 

assistance.

L A - F M   I N S T A L L A T I O N   M A N U A L   &   U S E R   G U I D E 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Summary of Contents for LA-1000-FM

Page 1: ...ount Media Air Cleaner Distributed by Pure n Natural Systems Inc purennatural com 1 800 237 9199 COMMERCIAL AIR CLEANER INSTALLATION MANUAL AND USER GUIDE L A F M I N S T A L L A T I O N M A N U A L U...

Page 2: ...M General Information 8 Application 8 8 Sizing Maintenance 9 9 9 Washing the Electric Cells and Prefilter Replacing the HEPA Media Pad Service 9 Troubleshooting Guide and Chart Diagnostic Checks Power...

Page 3: ...exhausting of polluted air to the outside is the most common solution to the removal of concentrations of polluted air In doing so however you must also bring supplies of fresh air to take the place...

Page 4: ...ust Grille Mounting System Two speed Blower Switch System Light Piggyback Fuse System Power Supply Module Not used with HEPA Units Blower Motors COMPONENTS OF THE LAFM AND HEPA LAFM 4 Hood Assembly Th...

Page 5: ...LAFM Self Contained Flush Mounted Electronic Air Cleaner removes the smoke dust dirt pollen and other pollutants from the air with an electrostatic process which works this way 1 The internal circula...

Page 6: ...the cell 3 After removing the items in the previous step close and lock the hinged intake panel Preparation for Mounting The LAFM and HEPA LAFM are designed to fit into a T bar drop ceiling Remove as...

Page 7: ...cal authority Reassembly of the Unit 1 With the unit now in place loosen the 1 4 turn screws on the intake grille and allow the hinged portion to drop down 2 Replace the prefilter screen electronic ce...

Page 8: ...de air quality How fast is the level of contamination rising What kind of air speed is anticipated ASHRAE Standard 62 81 recommends several different air change formulas depending on the type of estab...

Page 9: ...ir cleaners and their components are susceptible to damage Take care when working with them to avoid equipment damage Replacing the HEPA Media Pad The HEPA Media pad cannot be cleaned and MUST BE REPL...

Page 10: ...ping sound and arcing should occur if the cell is properly energized b If no arcing is heard check for continuity through the collector cell then check for failure of the cell due to broken wires crac...

Page 11: ...ty component or connection in the power supply of your LAFM CAUTION EXPOSURE TO LINE VOLTAGE IN THIS PROCEDURE WARRANTS SPE CIAL CARE BE SURE THE POWER IS TURNED OFF BEFORE CONNECTING OR DIS CONNECTIN...

Page 12: ...nsure that any malfunction in the electronic air cleaner is quickly and properly repaired Refer first to flow chart below for an outline of the procedure and then refer to the Troubleshooting Guide 12...

Page 13: ...E FROM POWER SUPPLY IN LAFM BROWN OR WHITE WIRE FROM POWER SUPPLY IN LAFM GREEN GROUND WIRE FROM POWER SUPPLY IN LAFM NEUTRAL CONDUCTOR WIRE GREEN GROUND WIRE L A F M I N S T A L L A T I O N M A N U A...

Page 14: ...RLOCK MICRO SWITCH 497576 497567 ON OFF SWITCH 497612 497612 MOTOR BLOWER 497602 497609 FUSE 497547 497547 INDICATOR LAMP 497570 497592 POWER SUPPLY 10079 10179 L A F M I N S T A L L A T I O N M A N U...

Page 15: ...Electronic Filter Cell HEPA Media pad with integrated carbon filter 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Other parts in the LAFM assembly can be obtained by calling our Customer Service Department MODEL LAFM P...

Page 16: ...ny part thereof which has not been operated in accordance with the operating instruc tions herein contained where components or other accessories not compatible with the LakeAir Electronic Air Cleaner...

Reviews: