Pure n Natural Systems LA-1000-FM Installation Manual And User'S Manual Download Page 10

MODEL LAF

M

 

TROUBLESHOOTING GUIDE AND CHART 

WARNING!!! The following instructions are intended for qualified service personnel only.   Dangerous line voltage circuits are 
exposed during these procedures.  Disconnect power at fuse before servicing the unit.  Trouble shooting the LAF

M

 can be 

accomplished with minimal tools and by following the directions given below in the two sections of Troubleshooting Guide.  The 
first section deals with checks on determining the cause of a malfunction in your LAF

M

, and the second section explains how to 

find a faulty component, or how to determine that a specific com-ponent is functioning properly. 

Diagnostic Checks 

1.

Powering up the LAF

M

a.

Make sure the prefilter screen and electronic filter are clean, dry, and pr

 

installed  in the air cleaner.

b.

Turn on the LAF

M

 and check to make sure all systems are in proper working order.  In

 

each case, the system light should

 

be on and the fan should run.
-If the light does not come on, check the microswitch interlock for free movement as

 

well at the power source for correct

 

input.
-If the fan does not come on, check the fan motor, wiring to the motor, and
the power source.
-If both the system light and the fan motor operate, go to step 2.

c.

Test Technique 

a.

With the air cleaner turned on, use a long shank insulated screw driver to penetrate

 

the pre filter screen and make contact

with the electronic cell.  A definite “snapping”

 

sound and arcing should occur if the cell is properly energized.

b.

If no arcing is heard, check for continuity through the collector cell, then check for

 

failure of the cell due to broken wires,

cracked insulators, bent plates; and following

 

that, a possible failure in the voltage doubler or transformer.

d.

Cell Check

a.

To remove the electronic cell from the unit, loosen the two quarter turn fasteners and

 

allow the hinged intake to drop into

place.  Remove the grid cap connector from the

 

cell and take the cell and pre filter from the unit.

b.

Close the hinged intake and check to see if the system light and the fan operate.  If

 

they do, check the cell for a short

circuit.

c.

Replace the cell.  If the Test Technique still does not produce a “snap” or arcing, go to

 

step

 

4.

e.

Check Power Supply

a.

Remove the power supply from the LAF

M

 cabinet and check for continuity through the

 

circuit.

b.

Check continuity through the switch and go back through to the power source until the

 

problem can be located.

c.

Replace the power supply into the cabinet and check for correct line voltage by

 

powering up the system and using a

 

voltmeter to measure the input voltage at the

 

transformer.

d.

If voltage is correct (about 120V AC), then continue to check voltage at the secondary

 

side of the transformer (2000V

 

AC), and finally at the output (grid cap connector)

 

which should yield about 6000V DC.

e.

Any variation from these voltages could indicate a component failure where

 

replacement may be required. 

10 

L A - F M   I N S T A L L A T I O N   M A N U A L   &   U S E R   G U I D E 

Pure n Natural Systems, Inc.  |  purennatural.com  |  1-800-237-9199

Summary of Contents for LA-1000-FM

Page 1: ...ount Media Air Cleaner Distributed by Pure n Natural Systems Inc purennatural com 1 800 237 9199 COMMERCIAL AIR CLEANER INSTALLATION MANUAL AND USER GUIDE L A F M I N S T A L L A T I O N M A N U A L U...

Page 2: ...M General Information 8 Application 8 8 Sizing Maintenance 9 9 9 Washing the Electric Cells and Prefilter Replacing the HEPA Media Pad Service 9 Troubleshooting Guide and Chart Diagnostic Checks Power...

Page 3: ...exhausting of polluted air to the outside is the most common solution to the removal of concentrations of polluted air In doing so however you must also bring supplies of fresh air to take the place...

Page 4: ...ust Grille Mounting System Two speed Blower Switch System Light Piggyback Fuse System Power Supply Module Not used with HEPA Units Blower Motors COMPONENTS OF THE LAFM AND HEPA LAFM 4 Hood Assembly Th...

Page 5: ...LAFM Self Contained Flush Mounted Electronic Air Cleaner removes the smoke dust dirt pollen and other pollutants from the air with an electrostatic process which works this way 1 The internal circula...

Page 6: ...the cell 3 After removing the items in the previous step close and lock the hinged intake panel Preparation for Mounting The LAFM and HEPA LAFM are designed to fit into a T bar drop ceiling Remove as...

Page 7: ...cal authority Reassembly of the Unit 1 With the unit now in place loosen the 1 4 turn screws on the intake grille and allow the hinged portion to drop down 2 Replace the prefilter screen electronic ce...

Page 8: ...de air quality How fast is the level of contamination rising What kind of air speed is anticipated ASHRAE Standard 62 81 recommends several different air change formulas depending on the type of estab...

Page 9: ...ir cleaners and their components are susceptible to damage Take care when working with them to avoid equipment damage Replacing the HEPA Media Pad The HEPA Media pad cannot be cleaned and MUST BE REPL...

Page 10: ...ping sound and arcing should occur if the cell is properly energized b If no arcing is heard check for continuity through the collector cell then check for failure of the cell due to broken wires crac...

Page 11: ...ty component or connection in the power supply of your LAFM CAUTION EXPOSURE TO LINE VOLTAGE IN THIS PROCEDURE WARRANTS SPE CIAL CARE BE SURE THE POWER IS TURNED OFF BEFORE CONNECTING OR DIS CONNECTIN...

Page 12: ...nsure that any malfunction in the electronic air cleaner is quickly and properly repaired Refer first to flow chart below for an outline of the procedure and then refer to the Troubleshooting Guide 12...

Page 13: ...E FROM POWER SUPPLY IN LAFM BROWN OR WHITE WIRE FROM POWER SUPPLY IN LAFM GREEN GROUND WIRE FROM POWER SUPPLY IN LAFM NEUTRAL CONDUCTOR WIRE GREEN GROUND WIRE L A F M I N S T A L L A T I O N M A N U A...

Page 14: ...RLOCK MICRO SWITCH 497576 497567 ON OFF SWITCH 497612 497612 MOTOR BLOWER 497602 497609 FUSE 497547 497547 INDICATOR LAMP 497570 497592 POWER SUPPLY 10079 10179 L A F M I N S T A L L A T I O N M A N U...

Page 15: ...Electronic Filter Cell HEPA Media pad with integrated carbon filter 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Other parts in the LAFM assembly can be obtained by calling our Customer Service Department MODEL LAFM P...

Page 16: ...ny part thereof which has not been operated in accordance with the operating instruc tions herein contained where components or other accessories not compatible with the LakeAir Electronic Air Cleaner...

Reviews: