background image

UNPACKING AND OPERATING INSTRUCTIONS 

To operate your AirMac-750E Air Cleaner properly, it is necessary to remove plastic 
packing material from the carbon after-filter inside the unit. Follow the step–by–step 
instructions and you will soon be enjoying clean fresh air! 

1. Remove the two fasteners and the variable speed control knob from the top of the

cabinet.

2. Lift the cover assembly from the chassis and set aside.

3. Remove the carbon after-filter from behind the cell. Take off the protective packing

material and discard.

4. Replace the carbon after filter, then the cover assembly, making sure to include

both fasteners and the variable speed control knob.
NOTE: The fasteners must be in place and secured snugly or the unit will not 
operate.

5. Place your AirMac-750E Air Cleaner in a convenient area in the desired room. If you

are using the air cleaner for a specific purpose, such as smoke removal, locate the air
cleaner as close as possible to the source. (Such as near a smoking stand.) Care
should be taken to allow at least 4-6” of unobstructed space behind the unit so that it
will Exhaust freely into the room. If, however, you position the unit so that the
airflow is parallel to the nearest wall, you need not to allow as much free space. For
best results the unit should be elevated by placing it on a table or stand. It can also
be mounted on a wall, using our convenient wall mount option.

6. Plug the line cord into a standard household outlet with 120V AC 60 Hz (230 models

require 230 V AC 50 Hz). Caution should be taken to use the unit only on the
required voltage, as to do otherwise will void the warranty.

OPERATING INSTRUCTIONS 

Position the unit and plug it into the proper line voltage before turning it on. 
To turn unit on, locate the variable speed control on top of the unit. Under normal 
conditions, the Low position is adequate to keep an average size room clean. With 
excessive amounts of dust, smoke, or other pollutants present, the air cleaner should be 
operated on high.   

NOTE:    It  should  be  noted  that  occasionally,  a  large  particle  will  pass  through  the  electronic  cell  and  an 
arcing will occur, resulting in an audible cracking sound. This is normal and will not cause any damage to the 
unit. 

Pure n Natural Systems, Inc.  |  https://purennatural.com  |  1-800-237-9199

Summary of Contents for AirMac-750E

Page 1: ...AirMac 750E Owner s Manual Installation Guide Distributed by Pure n Natural Systems Inc 1 800 237 9199 https purennatural com...

Page 2: ...ve objectionable odors from the cleaned air and is available in the following Standard Carbon Mild Smoke and Odors SUPER Carbon Three 3 full pounds of Granular Activated Carbon will help to adsorb hea...

Page 3: ...the collecting section they are trapped by the collector plates much like a magnet attracts and collects metal filings 3 Finally the ACTIVATED CARBON AFTER FILTER removes all types of odors and VOCs a...

Page 4: ...unobstructed space behind the unit so that it will Exhaust freely into the room If however you position the unit so that the airflow is parallel to the nearest wall you need not to allow as much free...

Page 5: ...o soak it in a container of hot water into which has been dissolved a cup of dishwasher detergent or other cleaner that is safe for aluminum After soaking for 10 15 minutes agitate the filter cell in...

Page 6: ...low the vibration is increased to the point where an audible hum may he noted It usually occurs more in the northern sections of the country during the winter months This condition can be aggravated i...

Page 7: ...Unit not effectively cleaning the air Electronic filter cell dirty Clean according to instructions Electronic filter cell is not properly installed Check reassemble instructions Continuous arcing or...

Page 8: ...the sale of the described AirMac 750E M M Electronic Air Cleaner In no case will any claim for consequential damages or labor expenses be allowed This warranty does not apply to an AirMac 750E M M El...