![Pure line PL2605 Installation And User Manual Download Page 10](http://html1.mh-extra.com/html/pure-line/pl2605/pl2605_installation-and-user-manual_1627031010.webp)
Mains Connection
Pin #
Wire Color
Description
L1
Black
Hot 1
L2
Red or White
Hot 2
Green Screw
Green
Earth
Communication Connection
Pin #
Wire Color
Description
J201-1
Red
+12 V
J201-2
Black
A
J201-3
Yellow
B
J201-4
Green
COM
Voltage
Voltage at motor cannot exceed more than 10% above or below the rating listed on the
motor label. Improper voltage can cause your motor to overheat, causing overload
tripping and a reduced component life. If the voltage is running at less than 90% or
more than 110$ of rated voltage when motor is running t full load, consult power
company.
Grounding and Bonding
Install, ground, bond, and wire motor in accordance with local or national electrical code
requirements. Also use the correct size and type of wiring that is required by code.
Permanently ground the motor. Connect motor ground terminal to electrical service
ground. Bond motor to pool structure. Bonding will connect all metal parts within and
PURELINEPOOL.COM
TEL: 407-834-2200
9