background image

Contents

1.0 Precautions for handling the machine prior 

to installation

................................................................................1.

  1.1 Safety precautions...................................................................1.

  1.2 Notes for receiving the order...................................................1.

  1.3 Inspection................................................................................1.

  1.4 Storage....................................................................................1.

  1.5 Space reserved for installation................................................2.

2.0 Machine design

..................................................................2.

3.0 Machine installation

..........................................................3.

  3.1 Installation location selection...................................................3.

  3.2 Molecular filter module.............................................................3.

  3.3 Particle filter.............................................................................3.

  3.4 Post-activation inspection........................................................3.

4.0 Machine start and control

..............................................3.

5.0 Machine maintenance

.....................................................4.

  5.1 Replacement of parts and filter materials................................4.

  5.2 Special preventive measures...................................................4.

  5.3 Filtration, material stain removal..............................................4.

6.0 Warranty

................................................................................5.

7.0 Troubleshooting

..................................................................5.

8.0 Filter material sampling record

...................................5.

Summary of Contents for PuraShield 1000

Page 1: ...lation Operation Maintenance Manual The company reserves the right of final interpretation of the user manual Purafil Filtration Technology Guangzhou Co Ltd Company address 5th Floor Building 8 Tianqin Hi Tech Park Xintang Guangzhou China Zip code 511300 www purafil com ...

Page 2: ...ine design 2 3 0 Machine installation 3 3 1 Installation location selection 3 3 2 Molecular filter module 3 3 3 Particle filter 3 3 4 Post activation inspection 3 4 0 Machine start and control 3 5 0 Machine maintenance 4 5 1 Replacement of parts and filter materials 4 5 2 Special preventive measures 4 5 3 Filtration material stain removal 4 6 0 Warranty 5 7 0 Troubleshooting 5 8 0 Filter material sam...

Page 3: ... obvious or hidden damage due to shipping All product damages due to shipping should be handled between the customer and the machine s shipper If the machine is to be stored before use refer to Section 1 4 of this manual If you want to install the machine immediately refer to Section 1 5 of this manual Cut the packing straps open the carton remove the packing materials and take out the machine 1 3...

Page 4: ...e with relative humidity lower than 95 1 5 Space reserved for installation Space reserved for installation The machine should be installed in a place where the air inlet and outlet are not blocked The machine should be installed in a place convenient for loading and unloading the molecular filter module and the particle filter 2 0 Machine design 2 1 Product application PURFAFIL commercial air purifie...

Page 5: ... changes in these characteristics may affect the performance of the machine The particle filter can be customized according to specific application requirements Preliminary filter Slide the filter into the machine along the track Pay attention to the installation direction The air flow first passes through the thick white side Final filter Slide the filter into the machine along the track 3 4 Checklist fo...

Page 6: ...s of filter dust as it can cause sneezing A dust mask for protection is recommended when replacing filter material in a closed or airless space Water Avoid exposing the PURAFIL filter material to water or precipitation as this will dissolve the permanganate PURAFIL filter material should be stored in a dry environment with a relative humidity of less than 95 If human skin is exposed to permanganate so...

Page 7: ...ll other warranties express or implied including warranties of merchantability and fitness for purpose PURAFILmakes no warranty as to the merchantability of the goods or their suitability for any particular purpose PURAFIL shall not be liable for any loss or damage directly or indirectly caused by the use of such merchandise No person or company shall be entitled to any other liability for PURAFILi...

Page 8: ...PURAFIL product sales and service provider ...

Reviews: