PRODUCT LIMITED WARRANTY 

pura

DYN

® 

Bypass Oil Filtration System 

Limited Warranty 
 

The 

pura

DYN

 

bypass oil filtration system is warranted to be free from defects in material and workmanship for a period of five (5) years 

from the date of purchase, with the exception of the heating element which is warranted for one (1) year from the date of purchase.  All 
optional, off-the-shelf, third party parts are not warranted.  This warranty is only available to the original end-user purchaser and is not 
assignable or transferable.  You MUST return the registration card completely filled out (or register and submit the online registration 
form at www.puradyn.com) within 30 days of your purchase as a condition precedent to receive coverage and performance under o ur 
warranty.  Further, your failure to provide proof of purchase, which clearly states the date of purchase, shall void this warranty and the 
obligations and rights hereunder. 
 
The 

pura

DYN

,  including  any  defective  part  therein,  must  be  returned  to  an  authorized  sales  representative,  dealer,  distributor,  or  to 

Puradyn  within  the  material  and  workmanship  warranty  period.    The  sales  representative,  dealer,  distributor,  or  Puradyn  will  then 
execute the warranty procedures on the owner’s behalf.  Puradyn’s responsibility in respect to warranty claims is limited to providing the 
required repairs or replacements to the product itself, and no claim of breach of warranty shall be cause for cancellation or rescission of 
the contract of sale of any Puradyn products.   

For  warranty  questions  or  issues,  please  contact:    Puradyn  Filter  Technologies  Incorporated,  Attention:  Warranty  Department,  2017 
High  Ridge  Road,  Boynton  Beach,  FL  33426  USA    (T)  +1  561  547  9499.    If  the  product  is  not  free  from  defects  in  materials  and 
workmanship  during  the  warranty  period,  Puradyn,  at  its  option  and  expense  will  (i)  repair  the  subject  product  by  your  return  of  the 
product to Puradyn, (ii) replace the subject product by having the replacement sent to your location, or (iii) refund the purchase price for 
the product as identified in your proof of purchase.  In the event that without prior consultation with  Puradyn, repair work or any other 
change to the damage is executed, the right to warranty is invalidated and Puradyn is not bound to pay any compensation for damage.  
For other claims, including bodily injury based on the deficiency of the 

pura

DYN

 

system, the legal stipulations apply (see below). 

This warranty does not cover any economic loss, including without limitation, communication expenses, towing mechanic’s travel time 
and/or mileage, meals, lodging, loss of use of the engine or equipment, loss of time, revenue, inconvenience, cargo damage, premium 
charged for overtime labor requested by the purchaser, and for any service and/or maintenance, or any other cost or expense resulting 
from  a  defect covered  by  this  warranty.    Repairs  or  replacements  due  to  an accident,  failure  to follow  operating instructions,  misuse, 
alteration, misapplication, storage damage, negligence, modification exceeding 

pura

DYN

 

system specifications, or improper installation 

are not covered by this warranty.  The above-mentioned warranty and 

Puradyn’s liability will never extend beyond (the consequence of) 

defects in the 

pura

DYN

 

systems themselves.  Damage caused by other means or by third parties, such as errors during installation or 

by incorrect mounting of pieces of hoses, is not covered either by this warranty or by product liability.   

This Warranty expires if and when: 

a.  The 

pura

DYN

 

systems  are  handled  without  due  care  or  in  contradiction  with  the  instructions  for  use,  or  if  used  for 

purposes other than its appropriate purpose. 

b.  Cartridges other than the original

 pura

DYN

 

filter elements have been applied. 

c. 

The defect and/or damage is a result of a natural disaster, act of God, act of terrorism or military action, improper storage, 
embargoes, accident, misuse, incorrect use or any other outside cause 

or condition beyond Puradyn’s control. 

Puradyn  reserves  the  right  to  change  or  improve  the  design  of  any  Puradyn  product  without  assuming  any  obligation  to  modify  any 
Puradyn product previously manufactured.  The product may contain certain components that have been remanufactured or refurbished 
following limited prior use. 

 
EXCEPT AS STATED ABOVE, PURADYN SHALL NOT BE LIABLE IN CONTRACT, TORT, STRICT LIABILITY OR NEGLIGENCE FOR ANY DIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES 
OR  FOR  BREACH  OF  ANY  WRITTEN  OR  IMPLIED  WARRANTY.    PURADYN  NEITHER  ASSUMES  NOR  AUTHORIZES  ANY  OTHER  PERSON  TO  ASSUME  FOR  PURADYN  ANY  OTHER 
LIABILITY IN CONNECTION WITH THE SALE OF THE PRODUCT.  EXCEPT FOR THE EXPRESS WARRANTY STATED ABOVE, THERE 

ARE

 NO WARRANTIES EXPRESSED OR IMPLIED.  THIS 

WARRANTY SHALL BE GOVERNED BY AND CONSTRUED, INTERPRETED, AND ENFORCED IN ACCORDANCE WITH THE LAWS OF THE STATE OF FLORIDA, USA.  EXCLUSIVE VENUE 
AND JURISDICTION SHALL BE IN PALM BEACH COUNTY, FLORIDA, USA. 

19-00014_Product_Warranty_101907_Rev5

 

 

Summary of Contents for MTS 240

Page 1: ...19 00134_MTS40 240_Standard_Installation_Manual_082819_Rev3 Docx STANDARD INSTALLATION MANUAL puraDYN Bypass Oil Filtration Systems MTS 40 60 240...

Page 2: ...ENCE III Install Oil Return Gravity Flow Line 10 Unit Return Fitting Determine Oil Return Location Hose Routing 11 SEQUENCE IV puraDYN System Start Up 12 Sampling Oil Procedures 13 Oil Analysis Data I...

Page 3: ...As the oil travels through the filter element it passes through a time released additive package designed to replenish depleted base additives thereby maintaining the oil s chemical balance and visco...

Page 4: ...low filter element remains intact through an extended oil service interval 10 Prepare to take an oil sample from the drained oil to use as a reference of the current engine and oil condition 11 Prepar...

Page 5: ...st maintain a continuous downward slope Maintain enough space both horizontal and vertical so the unit including mounting hardware will not interfere with engine parts suspension components steering l...

Page 6: ...tion technical assistance please call Technical Support Toll free in North America at 1 866 PURADYN 866 787 2396 or 1 561 547 9499 CAUTION NOT RECOMMENDED to drill new holes or weld into equipment fra...

Page 7: ...lease also review metering jet assembly drawing for maintenance procedures Step 2 After locating the oil port that you will be connecting to use the 90 shutoff valve supplied from the kits bag and ins...

Page 8: ...e following manner a The shoulder nut has a reverse thread and must be screwed on in a counterclockwise direction As soon as the nut starts to thread insert the flared insert portion into the shoulder...

Page 9: ...been installed properly connect the pressure hose onto the shut off valve fitting and route the hose to the Unit Step 4 Connect supply pressure hose that was routed from the engine side Step 3 to the...

Page 10: ...th of hose has been pre determined Specification Use 5 8 I D 1 500 psi oil rated hose Puradyn part 08 00004 Parker 201 12 RL or equivalent NOTE Any equipment or application subject to harsh operating...

Page 11: ...e analyzed and compared with future oil analysis Install 5 8 Return hose onto the 90 elbow fitting or optional banjo fitting and connected to the oil drain plug hole Using supplied hose clamp to secur...

Page 12: ...Note Additional oil requirements for charging up the new or replacement puraDYN filter element For OEM full flow filters depending on size and orientation can hold an additional quantity of oil not s...

Page 13: ...ting temperature Open oil sample valve Draw off 1 cup of oil to purge sediment from oil sample valve Open oil sample bottle and draw off oil to fill until 3 4 full Close lid on bottle Fill out oil sam...

Page 14: ...ce is the interpretation of the test data Typical Oil Analysis Report usually presents the data in an easy to understand format and results Typical puraDYN oil analysis conducted by an independent lab...

Page 15: ...flow filter and take an oil analysis sample 3 Thereafter change the scheduled puraDYN replacement filter and perform oil analysis at the interval shown below or as oil analysis recommend or indicates...

Page 16: ...unit is not functioning properly check the following conditions and correct as indicated 1 Restricted oil flow Remedy Shutoff valve closed Open valve Filter dirty and clogged Replace with new filter...

Page 17: ...boats generators or any other types of industrial equipment with an engine or pressurized lubricating system Q Will the installation of the puraDYN System on my engine or other type of equipment affec...

Page 18: ...of the engine or the OEM full flow filter Q At what rate does the puraDYN System clean the oil A The puraDYN System cleans the oil at approximately 6 gallons per hour at 65 psi Q What is the puraDYN...

Page 19: ...ply hose from each supply fitting residual oil may still be present in fittings bypass system or hose Blow out the oil supply hose with high air pressure before proceeding to refastening supply hose F...

Page 20: ...OT 4 Remove the filter by firmly pulling up on the wire handle Note Be sure to save the new filter plastic bag and reuse for spent filter in order to prevent oil spills 5 Insert the new filter into th...

Page 21: ...rench 6 Cutting crimping and wire stripping pliers 7 Hacksaw 8 Utility knife 9 Center punch 10 Optional banjo fitting to make return hose connection to engine 11 3 16 I D high pressure hose 12 5 8 I D...

Page 22: ...claims including bodily injury based on the deficiency of the puraDYN system the legal stipulations apply see below This warranty does not cover any economic loss including without limitation communi...

Page 23: ...other than recommended oil changes 3 the puraDYN is installed on an engine in which the replacement engine oil meets or exceeds the engine manufacturer s recommended grade of engine oil 4 the proper p...

Page 24: ...EM Interval Engine Hours Hrs or Miles Log 0 hrs Log Log Log Log Oil Analysis Sample Sample Date Sample Date Sample Date Sample Date Sample Date puraDYN Filter Change Date Change Date Change Date Chang...

Page 25: ...N 787 2396 F 1 561 547 8629 http www puradyn com Protect Your Investment REGISTER YOUR PRODUCT FOR WARRANTY COVERAGE Online at www puradyn com Purchased by _________________________________ Date _____...