SEQUENCE ( III )
- Install Oil Return Line
Step 1.
Locate and install the return fitting into the oil drain plug port. You may use a 90° elbow
fitting or optional banjo fitting to simplify hose attachment.
Step 2.
Route the return hose to the bottom of the unit and connect to the O-Ring Face Seal
(ORFS) return fitting.
Note:
Banjo fittings are optional. They are NOT supplied with the
pura
DYN
®
unit.
The return and supply hoses are not included in the standard model, but can be supplied by
Puradyn Filter Technologies Incorporated, your dealer, or a local hydraulic parts store that
offers DOT rated hose. These hoses are sometimes custom made for specific application
where length of hose has been predetermined
.
Specification:
Use 13/32” I.D., 2000 psi, oil-rated hose, (Puradyn part# 08-00024, Parker 201-8
or equivalent).
Note:
A full braided steel hose should be used with
pura
DYN
®
System’s optional Off
Road Kit, whenever the return hose will be exposed to external debris or
rubbing. Please call Puradyn for consultation if equipment required this option.
2.
Optional Banjo fitting available with return hose to
be installed directly to oil pan / oil sump drain plug
location.
1.
Connect return
hose to return
fitting on the
bottom of the unit