SEQUENCE ( IV )
-
pura
DYN
®
System Start-Up
After (
pura
DYN
®
Bypass Oil Filtration System) installation is completed, please perform
the following System Start-up to ensure the
pura
DYN
®
System
is working properly:
1. Fill equipment with oil type and quantity as specified by OEM, and open shut-off
valve.
2. Start the engine, check for leaks. If no other issues arise, let engine run for 15 to 30
minutes and check all connections between engine &
pura
DYN
®
System again.
3. Shut engine down and let rest for 5 minutes.
4. Open lid and check for oil flow thru filter element. Close lid when done. Alternately,
the sample valve may be briefly opened to check for oil flow into unit.
5. Add make-up oil as indicated below (make sure to use same OEM specified oil)
.
Depending on size and orientation, OEM full flow filters can hold an additional quantity of oil not shown in the
oil makeup table above, please add oil as recommended by OEM.
Use the engine’s oil level dipstick to adjust or determine the proper oil level when installing or replacing oil
filters or when performing routine preventive maintenance
.
Whenever using a bypass filter element for the first time (new install or filter element replacement)
remember to allow time for the new bypass element to charge (completely fill with oil), and run for a few
minutes after it is charged (filtered oil returning to oil pan) before making final adjustments to the oil level
using the OEM oil level dipstick.
6. System Start-Up validated,
pura
DYN
®
System is ready to work.
Filter Model
Qty.
Unit
MTS-8 Filter
¾
Quarts
MTS-8X12 Filter
1 ½
Quarts
MTS-12 Filter
1 ½
Quarts
MTS-24
Filter
2 ¾
Quarts