background image

WHAT THE HEPA AIR CLEANER DOES 

The Console True HEPA Air Cleaner On Castors 

has been designed to remove particulate such as 

atmospheric  and  household  dust,  coal  dust, 

insecticide dust, mites, pollen, mold spores, fungi, 

bacteria, viruses, pet dander, cooking smoke and 

grease, tobacco smoke and more. It also removes 

odors  with  the  Carbon  Prefilter  and  the  Carbon 

VOC After Filter. 

 

BENEFITS 

 

Helps  provide  relief  from  allergies,  asthma, 

and other respiratory illness. 

 

Helps  reduce  housekeeping  time  and 

redecorating costs. 

 

Provides  a  healthier,  more  comfortable 

environment, year-round. 

 

HOW IT WORKS 

Millions  of  airborne  pollutants  are  carried  to  the 

Air  Cleaner  by  a  powerful  German  motor  where 

they  pass  through  the  side  Intake  Grills,  through 

to a 3-stage filtration system. 
The  Activated  Carbon  Prefilter  (activated  carbon 

impregnated polyester filter) first removes lint and 

odors before they enter the HEPA filter. 
Smaller  particles  then  pass  through  a  long-life, 

True HEPA (High Efficiency Particulate Air) Filter 

which  captures  99.97%  of  particles  0.3  micron 

(1/84,000 of an inch) and larger. This HEPA filter 

has more than 100 ft² of collection surface area. 
The  filtered  air  passes  through  a  Carbon  VOC 

After Filter to further remove odors. 
Clean air is discharged out the back Exhaust Grill, 

never blowing directly on room occupants. 

 

OPERATING INSTRUCTIONS

 

Remove the Air Cleaner from the box.  If your unit 

has any signs of damage, immediately contact the 

Dealer where the Air Cleaner was purchased. 
Keep  the  shipping  carton  and  packaging  in  case 

the need arises to store or transport the unit. 
Remove  all  packaging  from  the  unit.  Castors  are 

packaged  on  top  of  the  Air  Cleaner.  Open  top 

cover,  by  either  unlatching  the  catches  or 

removing the two screws from lid (non-tamperable 

model).  Remove castors, and screw in casters on 

bottom of unit. See Maintenance for installation of 

filters. 
Choose  a  suitable  location  to  allow  unobstructed 

circulation  from  the  sides  and  back  of  the  unit.  If 

unit has to be placed against a wall, allow at least 

6-8 inches (15-20 cm) for circulation. 
The Air Cleaner plugs into a regular outlet at the 

voltage shown on rating label. 
The  Control  Switch  for  the  Air  Cleaner  is  located 

on the rear of the unit. To turn the Air Cleaner on, 

rotate  the  Control  Switch  knob  clockwise.  This 

controls the power to the Fan.  When the  Control 

Switch  is  turned  just  past  the  click  position,  the 

fan is on high speed. Rotating the Control Switch 

completely clockwise reduces the fan speed to it’s 

lowest setting. 

 

The Air Cleaner is designed to run continuously 

to provide clean, filtered air 24 hours a day.  
The top cover must be secured for the Air Cleaner 

to operate. All filters must be in place for the unit 

to operate properly.

 

MAINTENANCE

 

For efficient operation, the filters must be changed 

on a regular basis. If you notice a reduction in air 

flow from the system, check the filters.  
1.  To access the filters, turn the Air Cleaner OFF 

at the switch and remove the top cover. 

2.  Carefully remove the filters to avoid spilling of 

collected contaminants. Dispose of filters in a 

plastic bag and discard with regular trash. 

3.  Remove  plastic  from  the  new  filters  before 

installing. Discard plastic safely. Take care not 

to damage the filters. 

4.  Date the replacement HEPA filter in the space 

provided. 

5.  Place  the  Carbon  prefilter  around  the  outside 

of the HEPA filter and secure with the Velcro 

strips. 

6.  Place  the  Carbon  VOC  After  filter  inside  the 

perimeter of the filter. 

7.  Place the HEPA filter into the cabinet insuring 

the open end of the filter is toward the motor. 

8.  Replace the filter hold down bar. 
9.  Replace the cover of the Air Cleaner.

 

 

10. Use genuine replacement filters only. 

Note: When the filters are new, you may notice a 

new smell from the system. This is normal and will 

dissipate within a few hours. 

The  outside  of  cabinet  and  grills  can  be  cleaned 

with a damp cloth. 

Carbon  Prefilter (Part #W4-0855):

  This must be 

replaced  every  3  -  6  months.  If  there  are  heavy 

odors  from  cooking,  smoking,  painting  or  other 

sources,  the  filter  will  require  changing  more 

often. 

CAUTION  

When replacing the filters wear disposable gloves 

and a dust mask. 

CAUTION  

Make  sure  to  turn  Air  Cleaner 

OFF

  before 

performing  any  maintenance  or  replacing  any 

filters.  

Summary of Contents for PD-HEPA375VSC

Page 1: ...to extend life of HEPA Filter Carbon VOC After Filter removes additional unpleasant odors and gases Castors for easy maneuvering Easy to operate East to change filters Easy to maintain Available with...

Page 2: ...t least 6 8 inches 15 20 cm for circulation The Air Cleaner plugs into a regular outlet at the voltage shown on rating label The Control Switch for the Air Cleaner is located on the rear of the unit T...

Page 3: ...rsonnel 6 Never push objects of any kind into the Air Cleaner through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock 7 If the...

Page 4: ...iling this PUR Distribution will guarantee the unit for a period of sixty 60 months from the date of manufacture according to the manufacturer s records THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL L...

Page 5: ...de vie du filtre HEPA Le filtre terminal de COV au charbon limine les odeurs et les manations d sagr ables suppl mentaires Filtres faciles changer Le caisson en acier d pais calibre et la peinture en...

Page 6: ...rtable pendant toute l ann e COMMENT IL FONCTIONNE Des millions d l ments polluants se d placent travers les conduites de retour d air du syst me de chauffage climatisation Le filtre air HEPA a t con...

Page 7: ...r vu 6 Placer le pr filtre au charbon autour du filtre HEPA et le fixer avec les attaches en Velcro 7 S assurer que le c t ouvert du filtre HEPA est orient vers le moteur et qu il est au del de la lig...

Page 8: ...5 watts D bit d air 305 pi 518 5 m hr Cordon d alimentation 10 0 ft 3 5 m Dimensions Pr filtre au charbon du filtre Filtre HEPA Filtre de COV au charbon 47 x 11 5 x 0 25 po 12 h x 14 25 dia x 2 375 po...

Page 9: ...n choc lectrique ou un risque d incendie 5 N essayez pas de r parer vous m me le purificateur d air car en ouvrant ou en retirant le couvercle de l interrupteur vous vous exposez une tension dangereus...

Page 10: ...limit es dans leur dur e la p riode pour laquelle la garantie limit e s applique Les garanties explicites donn es aux pr sentes sont exclusives et ne peuvent tre alt r es largies ou modifi es par un d...

Page 11: ......

Page 12: ...ER OR SCREW GUN USING TORQUE 4 not higher REMOVE CARBON PREFILTER BLANKET FROM INSIDE OF CABINET PART W4 0855 AND INSTALL ON THE OUTSIDE OF HEPA FILTER REMOVE INNER CARBON BLANKET FROM INSIDE CABINET...