True HEPA Filter (Part #W4-0840):

 Replace every 

4-5  years.  The  life  of  this  filter  depends  on  the 

amount  of  contaminants  in  the  air  and  the 

frequency in which the prefilter has been changed. 

Renovations  that  create  wood  or  drywall  dust  or 

similar  contaminants  will  shorten  the  life 

expectancy of the HEPA filter. 

Note: Handle the HEPA filter carefully. The paper 

is  fragile  and  a  puncture  or  tear  will  reduce 

efficiency. 
 

VOC  AFTER  Filter  (Part  #W4-0810): 

This filter is 

positioned  inside  the  HEPA  filter,  and  must  be 

replaced  every  6-12  months.  If  there  are  heavy 

odors  from  cooking,  smoking,  painting  or  other 

sources, the filter may require changing  

 

IMPORTANT SAFEGUARDS 

 

Safety points you should know about your Air Cleaner 

 

 

Caution: 

** Read Owner’s Manual and safeguards before using 

** Save Owner’s Manual for later use 

** Follow all warnings and instructions marked on Air Cleaner 

 

 

 

FOR YOUR PERSONAL SAFETY

 

1.  The Air Cleaner is equipped with a grounded plug.  

Do not defeat the purpose of this plug by removing 

the  grounding  pin,  as  this  may  result  in  an 

electrical shock or create an unsafe condition. 

2.  When  the  power  cord  or  plug  is  damaged  or 

frayed, unplug the Air Cleaner from the wall outlet 

and refer servicing to qualified service personnel. 

3.  Do  not  overload  wall  outlets  and  extension  cords, 

as this can result in fire or electric shock. 

4.  Do  not  allow  anything  to  rest  on  or  roll  over  the 

power cord, and do not place the unit where power 

cord is subject to traffic or abuse. This may result 

in a shock or fire hazard. 

5.  Do not attempt to service the Air Cleaner yourself 

as opening  or  removing switch cover may expose 

you to dangerous voltage or other hazards.  Refer 

all servicing to qualified personnel. 

6.  Never push objects of any kind into the Air Cleaner 

through  cabinet  slots,  as  they  may  touch 

dangerous  voltage  points,  or  short  out  parts  that 

could result in a fire or electric shock. 

7.  If the Air Cleaner has been dropped or the cabinet 

has  been  damaged,  unplug  the  unit  from  the  wall 

outlet  and  refer  servicing  to  qualified  service 

personnel.  

8.  Unplug the Air Cleaner from the wall outlet before 

cleaning.    Do  not  use  liquid  cleaners  or  aerosol 

cleaners on cabinet. Use a damp, lint-free cloth for 

cleaning. 

9.  Do not use the Air Cleaner near water, i.e. near a 

bathtub,  sink,  laundry  tub,  in  a  wet  basement,  in 

the rain or near a swimming pool, etc. 

 

If  liquid  has  been  spilled  into  the  Air  Cleaner, 

unplug  the  unit  from  the  wall  outlet  and  refer 

servicing to qualified service personnel. 

10.  Do not use the Air Cleaner near open fire or flame, 

or  sources  of  heat  i.e.  fireplaces,  wood  burning 

stoves, kerosene heaters, stove tops, ovens, etc. 

11.  Do  not  use  the  Air  Cleaner  on  soft  surfaces  i.e. 

beds, sofas. 

12.  Do not use the  Air Cleaner when oxygen  is  being 

used or when combustible gases are present. 

13.  The  Air  Cleaner  has  slots  or  openings  in  the 

cabinet for ventilation purposes, to provide reliable 

operation  of  the  unit,  and  to  protect  it  from 

overheating. These openings must not be blocked 

or covered. 

14.  The Air Cleaner should be operated only from the 

type of power source indicated on the rating label. 

If  you are not sure of the  type  of power supply at 

your home, consult your local power company. 

15.  If  the  Air  Cleaner  does  not  operate  normally  by 

following the operating instructions, unplug the unit 

from the wall outlet and refer servicing to qualified 

service personnel. 

 

CAUTION  

USE ORIGINAL OEM REPLACEMENT FILTERS 

ONLY.  THIS  UNIT  HAS  BEEN  CSA/UL 

APPROVED 

WITH 

ELECTRO-AIR 

OEM 

FILTERS. 

USING  ANY  OTHER  FILTERS  MAY  CAUSE 

ODORS,  FUMES  OR  DAMAGE  TO  THE 

MOTOR OR FAN. 

WARRANTY WILL BE VOID. 

Summary of Contents for PD-HEPA375VSC

Page 1: ...to extend life of HEPA Filter Carbon VOC After Filter removes additional unpleasant odors and gases Castors for easy maneuvering Easy to operate East to change filters Easy to maintain Available with...

Page 2: ...t least 6 8 inches 15 20 cm for circulation The Air Cleaner plugs into a regular outlet at the voltage shown on rating label The Control Switch for the Air Cleaner is located on the rear of the unit T...

Page 3: ...rsonnel 6 Never push objects of any kind into the Air Cleaner through cabinet slots as they may touch dangerous voltage points or short out parts that could result in a fire or electric shock 7 If the...

Page 4: ...iling this PUR Distribution will guarantee the unit for a period of sixty 60 months from the date of manufacture according to the manufacturer s records THIS WARRANTY DOES NOT INCLUDE ANY ADDITIONAL L...

Page 5: ...de vie du filtre HEPA Le filtre terminal de COV au charbon limine les odeurs et les manations d sagr ables suppl mentaires Filtres faciles changer Le caisson en acier d pais calibre et la peinture en...

Page 6: ...rtable pendant toute l ann e COMMENT IL FONCTIONNE Des millions d l ments polluants se d placent travers les conduites de retour d air du syst me de chauffage climatisation Le filtre air HEPA a t con...

Page 7: ...r vu 6 Placer le pr filtre au charbon autour du filtre HEPA et le fixer avec les attaches en Velcro 7 S assurer que le c t ouvert du filtre HEPA est orient vers le moteur et qu il est au del de la lig...

Page 8: ...5 watts D bit d air 305 pi 518 5 m hr Cordon d alimentation 10 0 ft 3 5 m Dimensions Pr filtre au charbon du filtre Filtre HEPA Filtre de COV au charbon 47 x 11 5 x 0 25 po 12 h x 14 25 dia x 2 375 po...

Page 9: ...n choc lectrique ou un risque d incendie 5 N essayez pas de r parer vous m me le purificateur d air car en ouvrant ou en retirant le couvercle de l interrupteur vous vous exposez une tension dangereus...

Page 10: ...limit es dans leur dur e la p riode pour laquelle la garantie limit e s applique Les garanties explicites donn es aux pr sentes sont exclusives et ne peuvent tre alt r es largies ou modifi es par un d...

Page 11: ......

Page 12: ...ER OR SCREW GUN USING TORQUE 4 not higher REMOVE CARBON PREFILTER BLANKET FROM INSIDE OF CABINET PART W4 0855 AND INSTALL ON THE OUTSIDE OF HEPA FILTER REMOVE INNER CARBON BLANKET FROM INSIDE CABINET...

Reviews: