SAFETY FIRST !

WARNING

WARNING INDICATES A POTENTIALLY 

HAZARDOUS SITUATION WHICH, IF NOT 

AVOIDED, COULD RESULT IN DEATH, SERIOUS 

INJURY OR MAJOR PROPERTY DAMAGE.

This instruction manual contains very important information for you to know and understand.  This 

information is provided for your safety and to help prevent equipment problems from occurring. Please 

observe all safety information labeled danger, warning and caution.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS RISK, OBSERVE THE FOLLOWING 

WARNINGS:

WARNING! 

 To reduce the risk of electrical shock, this system must be properly grounded in accordance with 

the National Electric Code (NEC) and all applicable state and local codes and ordinances. The receptacle should be 
protected with a Ground Fault Circuit Interrupter (GFCI).

WARNING! 

  To reduce the risk of electrical shock, always disconnect the pump / system from the power source and 

battery BEFORE handling or servicing.

WARNING!  

Never remove the ground prong from the plug, or use an adapter that eliminates the ground prong.

WARNING! 

  Never plug this pump system into an electric outlet while standing on a wet surface.

WARNING! 

 Cables should be protected at all times to avoid punctures, cuts and abrasions that may result in exposed 

wiring. Never handle connected power cords with wet hands.

WARNING!

  The PumpSpy

 System has not been investigated for use in or around swimming pools, marine areas, 

recreational water installations, decorative fountains or any installation where human contact with the pumped fluid is 

common. 

WARNING! 

Do not use an extension cord. Extension cords could present a safety hazard if not properly sized, 

become damaged or the connection falls into the sump pit. Do not attempt to disassemble the PumpSpy controller or 

Backup Pump. There are no field serviceable parts or repair options! 

RISK OF EXPLOSION.  TO REDUCE THIS RISK, OBSERVE THE FOLLOWING 

WARNINGS:

WARNING!  Do not use to pump flammable or explosive liquids such as gasoline, fuel oil, kerosene, etc. 

WARNING!  Do not use in a flammable or explosive atmosphere. 

NOT SUITED FOR POTABLE WATER APPLICATIONS. 

WARNING! 

 Do not use this pump to transfer water that will be used for potable (drinking) water.  This pump is only 

to be used in applications for which it is designed.

CAUTION INDICATES A POTENTIALLY HAZARDOUS 

SITUATION WHICH, IF NOT AVOIDED, MAY RESULT IN  

MINOR INJURY OR PROPERTY DAMAGE.

CAUTION

TO REDUCE THE RISK OF HAZARDS THAT CAN CAUSE INJURY OR PROPERTY 
DAMAGE, OBSERVE THE FOLLOWING WARNINGS:

CAUTION!  Do not use discharge hose. Discharge hose may whip under pressure. Use rigid piping and fittings to 

secure the pump in the sump basin to reduce movement.

CAUTION! 

Do not install the pump if it has been damaged in any way. 

CAUTION! 

Do not carry or lift the pump by the power cord. Use the pump’s lifting handle.

© PumpSpy Technology, LLC   Questions? 

Call Tech Support: 515.999.6935

Summary of Contents for PS1000

Page 1: ... MAX Flow 12VDC Brushless DC 18 Amps 40 F to 120 F 1 1 2 NPT 3000 GPH System Solid State Pump Controller Power Supply Requirements Electrical Ratings Relative Humidity Storage Temperature Operating Temperature 120VAC 60 Hz 15 AMP 12Amps 120VAC 18 Amps 12VDC 0 to 80 0 to 70 C 0 to 50 C SPECIFICATIONS PumpSpy PS1000 PumpSpy Tech Support 515 999 6935 support PumpSpy com 34000 LEAR INDUSTRIAL PARKWAY ...

Page 2: ...ot been investigated for use in or around swimming pools marine areas recreational water installations decorative fountains or any installation where human contact with the pumped fluid is common WARNING Do not use an extension cord Extension cords could present a safety hazard if not properly sized become damaged or the connection falls into the sump pit Do not attempt to disassemble the PumpSpy ...

Page 3: ...harge 2 Cut a 3 ft section of 1 1 2 in rigid PVC pipe Glue 1 1 2 in pipe to a threaded fitting 3 Screw pipe from step 2 into pump discharge 4 Place the pump with the 3 ft section of PVC pipe on a solid level surface in the sump pit Do NOT place the pump on a loose or sandy surface Small stones or sand may damage the pump resulting in pump failure 5 Attach a check valve sold separately to the top o...

Page 4: ...od 2 8 Glue a short piece of PVC pipe between the 45º elbow and the Y THE CHECKVALVES FOR BOTH PUMPS MUST BE INSTALLED BELOWTHE Y FITTING The remainder of the discharge pipe installation will vary depending on individual circumstances Using sound plumbing practices route the discharge pipe to an exterior wall by the shortest distance AFTER PLUMBING IS COMPLETED FOR BOTH METHODS 1 AND 2 Install flo...

Page 5: ...battery case and place 12Volt battery inside 8 Connect the PumpSpy controller to the battery Red to Black to Replace and lock lid on case 9 Plug the PumpSpy controller into an AC outlet Consult your local codes for GFCI requirements 10 The PumpSpy system will initialize and boot up After booting the POWER and SYSTEM lights should be GREEN The DATA light should be BLINKING RED TESTTHE SYSTEM INTHIS...

Page 6: ...ite click the Login Activate button The website will walk you through the registration process step by step A valid credit card is required to activate the PumpSpy Remote Monitoring Service Your card will not be charged until the 30 day trial period expires There is no long term commitment and you can cancel the service at any time For terms and conditions visit www pumpspy com ACTIVATE THE PUMPSP...

Page 7: ...ds normal value Voltage Low Displayed when battery voltage drops below 11 4 volts 50 discharged Voltage Critical Displayed when battery voltage drops below 10 4 volts 90 discharged Primary Hi Amps Displayed when primary pump current exceeds baseline amp reading by 50 System Error Displayed when alarm for an alert is muted Sig Strgth xx Display of signal strength as read from cellular module press ...

Page 8: ...service cost of shipping will be paid one way This warranty does not cover products purchased from a party that is not an authorized retailer dealer or distributor of PumpSpy products OTHER IMPORTANT TERMS This warranty is not transferable and may not be assigned This warranty shall be governed and construed under the laws of the state of Ohio The warranty period will not be extended by any replac...