3. Operation indication (see table 3) 

 
Table 3. Operation indication 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY 

GREEN LED LIGHT (Power) 
Indication of the switch's power 
supply 

 

 

OFF

 

– no power supply of the switch 

ON

 

– power supply on, normal operation 

 

OPTICAL INDICATION AT THE PoE PORTS (1

÷8) 

 
GREEN LED LIGHT (PoE) 
Indication of the PoE power supply 
at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected or not compliant with               

the IEEE802.3af/at standard) 

ON

 

– power supply at the RJ45 port 

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10/100/1000 Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected; 10/100/1000 Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UP LINK PORTS 

GREEN LED LIGHT 

 

 

OFF

- no connection / the device is connected  10 Mb/s or 100 Mb/s 

ON 

- the device is connected  1000 Mb/s

 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10/100/1000 Mb/s 
and data transmission 

 

 

OFF

- no data transmission 

ON 

- the device is connected 10/100/1000 Mb/s 

Blinking

 

– data transmission 

 

 
 

 

 

 

WEEE LABEL 

 

Waste electrical and electronic equipment must not be disposed of with normal household waste. 

According to the European Union WEEE Directive, waste electrical and electronic equipment 

should be disposed of separately from normal household waste

.

 

 

 

 

 
 
 

 

 

 

Pulsar sp. j.  

Siedlec 150,  32-

744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

 

Summary of Contents for SG108

Page 1: ...m the production date Example of use 1 Technical description 1 1 General description SG108 is a 10 ports PoE switch designed to supply IP cameras operating in IEEE 802 3af at standard Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The UP LINK ports is used for connection of another network device via RJ45 connector The LEDs at the front...

Page 2: ...1 Block diagram 1 3 Description of components and connectors Table 1 see Fig 2 Element no Fig 2 Description 1 8 x PoE port 1 8 2 2 x UP LINK port 3 Power Socket of the DC 4 Additional assembly elements Fig 2 The view switch a ...

Page 3: ...ve humidity RH 90 maximum without condensation and temperature from 10 C to 40 C Ensure the free flow of air around the unit The PSU shall work in a vertical position that guarantees sufficient convectional air flow through ventilating holes of the enclosure The switch load balance should be done before installation The given value of 30 W per port is the maximum value referring to a single output...

Page 4: ...4 Connection schemes ...

Page 5: ... no connection ON the device is connected 10 100 1000 Mb s Blinking data transmission OPTICAL INDICATION AT THE UP LINK PORTS GREEN LED LIGHT OFF no connection the device is connected 10 Mb s or 100 Mb s ON the device is connected 1000 Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10 100 1000 Mb s and data transmission OFF no data transmission ON the device is connected 10 100 10...

Reviews: