3. Indication of the device operation. 
 

3.1 LED indication of operating status. 

The PSU is equipped with two diodes on the front panel: 

 

 
RED LED: 

 

on – the PSU is supplied with 230V AC  

 

off – no 230V AC supply 

 
GREEN LED: 

 

on – DC voltage in the AUX output of the PSU 

 

off – no DC voltage in the AUX output of the PSU 

 

 

 
3.2 Optical indication of the switch operation (see Table 8). 

 
Table 8. Indication of the switch operation 
 
 

OPTICAL INDICATION OF THE SWITCH's POWER SUPPLY 

GREEN LED LIGHT (Power) 
Indication of the switch's 
power supply 

 

 

OFF

 

– no power supply of the switch 

ON

 

– power supply on, normal operation 

 

OPTICAL INDICATION OF THE PoE SWITCH's (1

÷8) 

 

GREEN LED LIGHT (PoE) 
Indication of the PoE power 
supply at the RJ45 ports 
 

 

 

OFF

- no power supply at the RJ45 port (the device is not connected or not compliant 

with the IEEE802.3af /at standard) 

ON

 

– supply at the RJ45 port  

Blinking

 

– short-circuit or output overload 

YELLOW LED LIGHT (LINK) 
The connection status of LAN 
devices, 10/100/1000Mb/s 
and data transmission 

 

 

OFF

- no connection 

ON 

- the device is connected; 10/100/1000Mb/s 

Blinking

 

– data transmission 

 

OPTICAL INDICATION AT THE UPLINK PORTS  

 

GREEN LED LIGHT 

 

 

 
OFF

- no connection/ the device is connected 10/100Mb/s 

ON 

– the device is connected 1000Mb/s 

 

YELLOW LED LIGHT (LINK) 
The connection status of 
LAN devices, 
10/100/1000Mb/s 
and data transmission 

 

 

OFF

- no data transmission 

ON 

- the device is connected 10/100/1000Mb/s 

Blinking

 

– data transmission 

 

 

Summary of Contents for SG108-CRB

Page 1: ...with space for two 17Ah 12V battery and offers the possibility of recorder installation The enclosure construction is compliant with the requirements of the General Data Protection Regulation GDPR the...

Page 2: ...The electricity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approxima...

Page 3: ...nverter 4 DC DC50SD converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Battery space for two 2 x 17Ah 12V connect the batteries in series 8 Space for a recorder 380x32...

Page 4: ...od Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30W per port is the maximum value The total power consumption should not exceed 120W whe...

Page 5: ...nd output circuits of the PSU I P O P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation...

Page 6: ...clips of the PSU The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with symbo...

Page 7: ...F THE PoE SWITCH s 1 8 GREEN LED LIGHT PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af a...

Page 8: ...the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to...

Reviews: