background image

 

 

        The  given  value  of  30W  per  port  is  the  maximum  value  referring  to  a  single  output.  The  total  power 
consumption should not exceed 120W when all PoE ports are being used

. The increased demand for power is 

particularly evident in the case of cameras with heaters or infrared illuminators - when launching these features, the 
power  consumption  increases  rapidly,  which  may  adversely  affect  the  operation  of  the  switch.  As  the  device  is 
designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch,  therefore  an  appropriate  overload 
protection shall be guaranteed in the power supply circuit. Moreover, the user shall be informed about the method 
of  unplugging  (usually  through  assigning  an  appropriate  fuse  in  the  fuse-box).  The  electrical  system  shall  follow 
valid standards and regulations. 

 

2.2.  Installation procedure 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 
2. Mount the PSU in a selected location and connect the wires.  
3. Connect the power cables (~230Vac) to L-N clips of the PSU.  
 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow 

and green wire coat of the power cable shall stick to one side of the terminal - marked 

with ‘

 symbol on the PSU enclosure. Operation of the PSU without the properly 

made and fully operational shock protection circuit is UNACCEPTABLE! It can cause a 

device failure or an electric shock. 

 

4. Connect the ground wire to the terminal marked with the 

 symbol (power supply module connector). Use a 

three-core cable (with a yellow and green PE protection wire) to make the connection. Lead the cables to the 
appropriate clips through the insulating bushing of the connection board.  
 
5. Connect the battery (mind the colours):   

          - battery output (+V):  BAT+ cable / red, 

- battery output (0V):  BAT 

– cable / GND / black. 

 
 
6. Connect the power (~230V). 
7. Connect the camera cables to the RJ45 connectors (PoE connectors) and connect the recorder to the network 
(the UPLINK connector). 
8. Connect the power supply of the DVR (by default, the device is equipped with a cable terminated with the DC 2,1/5,5 
plug). 
9. Check the optical indication of the switch operation. 
10. After installing and checking proper working, the enclosure can be closed. 

     

 

 Connection schemes 

 

 

 

Summary of Contents for SG108-CRB

Page 1: ...with space for two 17Ah 12V battery and offers the possibility of recorder installation The enclosure construction is compliant with the requirements of the General Data Protection Regulation GDPR the...

Page 2: ...The electricity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approxima...

Page 3: ...nverter 4 DC DC50SD converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Battery space for two 2 x 17Ah 12V connect the batteries in series 8 Space for a recorder 380x32...

Page 4: ...od Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30W per port is the maximum value The total power consumption should not exceed 120W whe...

Page 5: ...nd output circuits of the PSU I P O P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation...

Page 6: ...clips of the PSU The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with symbo...

Page 7: ...F THE PoE SWITCH s 1 8 GREEN LED LIGHT PoE Indication of the PoE power supply at the RJ45 ports OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af a...

Page 8: ...the disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to...