5
Deep discharge battery protection UVP
U<19V (± 5%) – disconnection of the batteries
Sabotage protection:
- TAMPER output indicating enclosure opening
- microswitch, NC contacts (enclosure closed),
0,5A@50V DC (max.)
Table 5. Mechanical parameters
Dimensions
W=421, H=535, D+D
1
=193+14 [+/- 2mm]
W
1
=426, H
1
=540 [+/- 2mm]
Dimensions of recorder
space
W
2
=380, H
2
=320, D
2
=65 [+/- 2mm]
The dimensions of the
battery compartment
370x180x80 (WxHxD)
Gross/Net weight
10,8 / 11,6 kg
Enclosure
Steel plate, DC01 1,0mm color white RAL 9003
Closing
Cheese head screw x 2 (at the front)
The possibility of installing two locks with different codes.
Connectors
Power supply of the cameras: RJ45 socket
Power supply for recorder: DC2,1/5,5 plug
230V AC input:
Φ 0,63-2,50 (AWG 22-10),
Battery output BAT: 6,3F-2,5
TAMPER output: wires
Notes
The enclosure does not touch the assembly surface so that cables can be led.
Table 6. Operation safety
Protection class PN-EN 609501:2007
I (first)
Protection grade PN-EN 60529: 2002 (U)
IP20
Electrical strength of insulation:
- between input and output circuits of the PSU (I/P-O/P)
- between input circuit and PE protection circuit (I/P-FG)
- between output circuit and PE protection circuit (O/P-FG)
3000 V/AC min.
1500 V/AC min.
500 V/AC min.
Insulation resistance:
- between input circuit and output or protection circuit
100 MΩ, 500V/DC
Declarations
CE
Table 7. Operating parameters
Operating temperature
-
10ºC...+40ºC
Storage temperature
-
20ºC...+60ºC
Relative humidity
20%...90%, without condensation
Vibrations during operation
unacceptable
Impulse waves during operation
unacceptable
Direct insulation
unacceptable
Vibrations and impulse waves during transport
According to PN-83/T-42106
2. Installation
2.1. Requirements
The device should be mounted by a qualified installer, holding relevant permits and licenses (applicable and
required for a given country) for 230V/AC and low-voltage installations.
The device shall be mounted in confined spaces, according to the environment class II, with normal air humidity
(RH=90% max. without condensation) and the temperature from -
10°C to +40°C.
The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of
the enclosure.
Before installation, prepare a Switch'a load balance.