background image

 

Closing 

Cheese head screw x 2 (at the front), (lock assembly possible) 

Notes 

The enclosure does not touch the assembly surface so that cables can be led. 

Gross/Net weight 

7,7 / 8,5 kg 

Protection class        
EN 60950-1:2007 

II (second) 

Storage temperature 

-

20ºC...+60ºC 

Declarations 

CE 

*

 

The given value of 30W per port is the maximum value. The total power consumption should not exceed 120W when all PoE ports are being used. 

 

2.  Installation. 

 

                2.1. Installation procedure. 

1.  The unit should be mounted by a qualified installer, holding relevant permits and licenses (applicable and required for a 

given country) for 230V/AC interference and low-voltage installations.  

2.  The unit should be mounted in confined spaces, in accordance with the 2nd environmental class, with normal relative 

humidity (RH=90% maximum, without condensation) and temperature from -

10°C to +40°C.  

3. The switch shall work in a vertical position that guarantees sufficient convectional air-flow through ventilating holes of the 

enclosure.  The  load  balance  should  be  done  before  installation  Switcha.  The  given  value  of  30W  per  port  is  the 
maximum value referring to a single output. The total power consumption should not exceed 120W when all PoE ports 
are being used. The increased demand for power is particularly evident in the case of cameras with heaters or infrared 
illuminators -  when launching these features, the power consumption increases rapidly, which may adversely affect the 
operation  of  the  switch.  The  device  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch. 
Therefore, an appropriate overload protection in the power supply circuit should be provided. Moreover, the user should 
be informed how to disconnect the power supply unit from the mains supply (usually by assigning an appropriate fuse in 
the fuse box). The electrical system shall be made in accordance with applicable standards and regulations.   

 

               2.2.  Installation procedure. 

1. Before installation, make sure that the voltage in the 230V power-supply circuit is cut off. 
2. Mount the PSU in a selected location and connect the wires.  
3. Connect the power cables (~230V) to the L-N terminals of the power supply.  
 

 

The shock protection circuit shall be performed with a particular care, i.e. the yellow and 

green wire coat of the power cable shall stick to one side of the terminal - marked with 

 symbol on the PSU enclosure. Operation of the PSU without the properly made and 

fully operational shock protection circuit is UNACCEPTABLE! It can cause a device 

failure or an electric shock

.

 

 

4. Connect the ground wire to the terminal marked by the earth symbol PE 

 (power supply module connector). Use a three-

core cable (with a yellow and green PE protection wire) to make the connection. Lead the cables to the appropriate terminals of 
the connection board through the insulating bushing.  
5. Connect the power (~230V).  
6. Connect the camera wires to the RJ45 connectors (PoE connectors). 
7. Check the optical indication of the switch operation. 
8. After installing and checking proper working, the enclosure can be closed. 
 

 

Connection schemes. 

 
 

 
 
 

 
 

 
 

 
 
 

 

Summary of Contents for SG108-CR

Page 1: ...RAL 9003 warranty 2 year from the production date Example of use 1 Technical description 1 1 General description The SG108 CR is a complete kit to build the CCTV system based on IP cameras The switch is placed in a metal enclosure with recorder space Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The UP LINK ports is used for connection...

Page 2: ...meter adjusting the output voltage of the power supply 48 53V 4 LED light power supply operation indication 5 T 6 3A 250V fuse socket 6 Mounting brackets for cables 7 Space for the power supply of the recorder desktop type of dimensions max 180x40x100 mm 8 Power Socket of the 230V AC recorder 9 Recorder space of dimensions max 400x345x95mm WxHxD 10 Straps for attaching the DVR in enclosure Fig 2 T...

Page 3: ...t each port Used pairs 4 5 7 8 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Output current at the PoE ports RJ45 8 x 0 6A ΣI 2 3A max Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status Mains supply 176 264VAC 50Hz 1 1A 230VAC Operating conditions Temperature 10 C 40 C relative humidity 5 90 no condensation D...

Page 4: ...ct the operation of the switch The device is designed for a continuous operation and is not equipped with a power switch Therefore an appropriate overload protection in the power supply circuit should be provided Moreover the user should be informed how to disconnect the power supply unit from the mains supply usually by assigning an appropriate fuse in the fuse box The electrical system shall be ...

Page 5: ... 1000Mb s and data transmission OFF no connection ON the device is connected 10 100 1000Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORTS GREEN LED LIGHT OFF no connection or device connected 10 100Mb s ON the device is connected 1000Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10 100 1000Mb s and data transmission OFF no data transmission ON the device is c...