    Table 2. (See Fig.3) 

Component No. 

(Fig. 3) 

Description 

[1] 

8 x PoE port (1

÷8) 

[2] 

2 x UPLINK port  

[3] 

52VDC power supply socket 

 

 

Fig. 3. The view switch'a. 

 

 

1.4.  Technical parameters (tab.3)  

 

Table 3.   

Ports 

10 ports 10/100/1000Mb/s (8 x PoE + 2 x UP LINK)  

              with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE802.3af/at (1

÷8 ports),  52V DC / 30W at each port  * 

Used pairs  4/5 (+),  7/8 (-) 

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Bandwidth 

1,6Gbps 

Output current at the PoE 
ports (RJ45) 

8 x 0,6

A ΣI=2,3A (max.) 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply; 

Link/Act; 

PoE Status 

Mains supply 

176 

÷ 264VAC 50Hz / 1,1A/230VAC 

Operating conditions 

Temperature -

10°C ÷ 40°C,  

relative humidity  5% - 90%, no condensation 

Dimensions 

W=432, H=607, D+D

1

=102+14 [+/- 2mm] 

W

1

=437, H

1

=612 [+/- 2mm] 

Recorder space 

W

2

=400, H

2

=345, D

2

=95 [+/- 2mm] 

Enclosure 

Steel plate, DC01 1,0mm color white RAL 9003 

Summary of Contents for SG108-CR

Page 1: ...RAL 9003 warranty 2 year from the production date Example of use 1 Technical description 1 1 General description The SG108 CR is a complete kit to build the CCTV system based on IP cameras The switch is placed in a metal enclosure with recorder space Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The UP LINK ports is used for connection...

Page 2: ...meter adjusting the output voltage of the power supply 48 53V 4 LED light power supply operation indication 5 T 6 3A 250V fuse socket 6 Mounting brackets for cables 7 Space for the power supply of the recorder desktop type of dimensions max 180x40x100 mm 8 Power Socket of the 230V AC recorder 9 Recorder space of dimensions max 400x345x95mm WxHxD 10 Straps for attaching the DVR in enclosure Fig 2 T...

Page 3: ...t each port Used pairs 4 5 7 8 Protocols Standards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Bandwidth 1 6Gbps Output current at the PoE ports RJ45 8 x 0 6A ΣI 2 3A max Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status Mains supply 176 264VAC 50Hz 1 1A 230VAC Operating conditions Temperature 10 C 40 C relative humidity 5 90 no condensation D...

Page 4: ...ct the operation of the switch The device is designed for a continuous operation and is not equipped with a power switch Therefore an appropriate overload protection in the power supply circuit should be provided Moreover the user should be informed how to disconnect the power supply unit from the mains supply usually by assigning an appropriate fuse in the fuse box The electrical system shall be ...

Page 5: ... 1000Mb s and data transmission OFF no connection ON the device is connected 10 100 1000Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORTS GREEN LED LIGHT OFF no connection or device connected 10 100Mb s ON the device is connected 1000Mb s YELLOW LED LIGHT LINK The connection status of LAN devices 10 100 1000Mb s and data transmission OFF no data transmission ON the device is c...