background image

 

1.3  Description of components and connectors. 

 

 

Fig. 2. The enclosure view. 

 

Table 1. Elements of the power supply. 

Component No. 

(Fig. 2) 

Description 

[1] 

16 ports PoE switch

 

[2] 

Switch mode buffer power supply unit 54VDC PSB-30048050 

[3] 

DC/DC50HV converter 

[4] 

Output filter in the power circuit of the recorder 

[5] 

Tamper

 

– terminals of tamper protection (NC) 

[6] 

Space for batteries 4x17Ah/12V 

[7] 

Space for a recorder (straps for mounting the recorder)  
with the following dimensions 

max. 400×345×80 W×H×D

 

[8] 

L-N  

power supply connector 230V/AC, 

 PE protective connector

 

[9] 

B+, B- :

 battery BAT red, -BAT black

 

[10] 

DVR power cord terminated with the DC 2.1/5.5 plug 

 
 
 
 

Summary of Contents for SF116-CRB

Page 1: ...aint with the IEEE802 3af standard Supports auto learning and auto aging of MAC addresses 1K size Space for a recorder with the following dimensions max 400 345 80 W H D LED indication Metal housing c...

Page 2: ...1 TP G2 TP ports is used for connection of another network device via RJ45 connector The switch is fitted with SFP slots the use of fiber optic module GBIC allows fiber optic transmission The LEDs at...

Page 3: ...050 3 DC DC50HV converter 4 Output filter in the power circuit of the recorder 5 Tamper terminals of tamper protection NC 6 Space for batteries 4x17Ah 12V 7 Space for a recorder straps for mounting th...

Page 4: ...dards IEEE802 3 802 3u 802 3x CSMA CD TCP IP Forwarding rate 10BASE T 14880pps port 100BASE TX 148800pps port Bandwidth 1 6Gbps Transmission method Store and Forward Optical indication of operation Sw...

Page 5: ...should not exceed 192W when all PoE ports are being used The increased demand for power is particularly evident in the case of cameras with heaters or infrared illuminators when launching these featur...

Page 6: ...PTICAL INDICATION OF THE SWITCH s POWER SUPPLY 1 16 GREE LED LIGHT LINK The connection status of LAN devices 10MB s or 100Mb s and data transmission OFF no connection ON the device is connected 10Mb s...

Page 7: ...n example of the SF116 CRB with batteries and the recorder DVR and accumulators are not included 4 Maintenance Any and all maintenance operations may be performed following the disconnection of the PS...

Page 8: ...pment should be disposed of separately from normal household waste The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycle...

Reviews: