Installation example of the S108-CRB with batteries and the recorder
(DVR and accumulators are not included)
4.
Operation and use.
4.1
Overload or short circuit of the PSU output (SCP on).
In case of overload, the output voltage is automatically shut off, and so is the LED indicator. The restoration of the voltage
takes place immediately after the failure (overload) is over.
4.2
Disconnection of discharged battery
.
The PSU is equipped with the discharged battery disconnection system. During the battery-assisted operation, reducing
voltage below 19 V at the battery terminals will cause battery disconnection.
4.3 Maintenance
.
Any and all maintenance operations may be performed following the disconnection of the PSU from the power supply
network. The PSU does not require performing any specific maintenance measures, however, in case of significant dust rate,
its interior is recommended to be cleaned with compressed air. In case of fuse replacement, use a replacement of the same
parameters.
WEEE LABEL
Waste electrical and electronic equipment must not be disposed of with normal household waste.
According to the European Union WEEE Directive, waste electrical and electronic equipment
should be disposed of separately from normal household waste
.
The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed of but recycled according to the