background image

 

 

Fig. 3. The view of the switch. 

 

Table 2. (See Fig.3) 

Component No 

(Fig. 3) 

Description 

[1] 

8 x PoE ports (1

÷8) 

[2] 

2 x UPLINK port  

[3] 

52 V DC power supply socket 

 

1.4  Technical parameters 

- parameters of the switch (tab.3) 
- electrical parameters (tab.4) 
- mechanical parameters

 

(tab.5) 

- operation safety (tab.6) 
- operating parameters (tab.7) 

 

Table 3.  Parameters of the switch 

Ports 

10 ports 10/100 Mb/s (8 x PoE + 2 x UpLink)                                                       

              with connection speed auto-negotiation and MDI/MDIX Auto Cross) 

PoE power supply 

IEEE 802.3af/at (1

÷8 ports),  52 V DC / 30 W at each port  * 

Used pairs  1/2 (+), 3/6 (-) 

Protocols, Standards 

IEEE802.3, 802.3u, 802.3x  CSMA/CD, TCP/IP 

Bandwidth 

1,6Gbps 

Transmission method 

Store-and-Forward 

Optical indication of 
operation 

Switch power supply; 

Link/Act; 

PoE Status 

*

 

The given value of 30 W per port is the maximum value. The total power consumption should not exceed 120 W. 

 

Table 4. Electrical parameters

 

Mains supply 

~200-240 V; 50 Hz 

Current up to 

1,3 A 

Supply power 

208 W  

Output current at the PoE ports (RJ45)

 

8 x 0,6 A 

ΣI=2,3 A (max.) 

Output voltage at the PoE ports (RJ45)

 

52 V DC  

Output current (recorder)

 

5 A 

Output voltage (recorder)

 

12 V DC 

Short-circuit protection SCP and overload protection OLP 

105% ÷ 150% of power supply, manual restart 

 (the fault requires disconnection of the DC output circuit) 

PSU current consumption 

300 mA / 27,6 V 

Battery charge current

 

1 A max.  / 2x17Ah (+/-5%) 

Approximate backup time 

3h 15min 

Battery circuit protection SCP and reverse  
polarity connection 

melting fuse 

Summary of Contents for S108-CRB

Page 1: ...space for two 17 Ah 12V battery and offers the possibility of recorder installation The enclosure construction is compliant with the requirements of the General Data Protection Regulation GDPR the possibility of installing two locks with different codes Space for a recorder with the following dimensions 380x320x65 WxHxD warranty 2 year from the production date Example of use CONTENTS 1 Technical d...

Page 2: ...es The electricity consumption for own needs and the energy efficiency of the power intake track were taken into account The exact description of how to perform the calculations can be found at Approximate backup time assumptions for calculations Automatic detection of any devices powered in the PoE PoE standard is enabled at the 1 8 ports of the switch The Up Link ports is used for connection of ...

Page 3: ... converter 4 DC DC50SD converter 5 Output filter 6 Tamper micro switch terminals of tamper protection NC 7 Battery space for two 2 x 17Ah 12V connect the batteries in series 8 Space for a recorder 380x320x65 WxHxD 9 Power supply connector of the PSU L N Protective connector electric shock 10 BAT BAT battery output BAT red BAT black 11 DVR power cord terminated with the DC 2 1 5 5 plug ...

Page 4: ...Transmission method Store and Forward Optical indication of operation Switch power supply Link Act PoE Status The given value of 30 W per port is the maximum value The total power consumption should not exceed 120 W Table 4 Electrical parameters Mains supply 200 240 V 50 Hz Current up to 1 3 A Supply power 208 W Output current at the PoE ports RJ45 8 x 0 6 A ΣI 2 3 A max Output voltage at the PoE ...

Page 5: ...n between input and output circuits of the PSU between input circuit and protection circuit between output circuit and protection circuit 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit and output or protection circuit 100 MΩ 500 V DC Declarations CE Table 7 Operating parameters Operating temperature 10ºC 40ºC Storage temperature 20ºC 60ºC Relative humidity 20 ...

Page 6: ...d connect the wires 2 Connect the power cables 230 V to L N clips of the PSU The shock protection circuit shall be performed with a particular care i e the yellow and green wire coat of the power cable shall stick to one side of the terminal marked with symbol on the PSU enclosure Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE It can c...

Page 7: ...rts OFF no power supply at the RJ45 port the device is not connected or not compliant with the IEEE802 3af at standard ON supply at the RJ45 port Blinking short circuit or output overload YELLOW LED LIGHT LINK The connection status of LAN devices 10 100Mb s and data transmission OFF no connection ON the device is connected 10 100Mb s Blinking data transmission OPTICAL INDICATION AT THE UPLINK PORT...

Page 8: ...e disconnection of the PSU from the power supply network The PSU does not require performing any specific maintenance measures however in case of significant dust rate its interior is recommended to be cleaned with compressed air In case of fuse replacement use a replacement of the same parameters WEEE LABEL Waste electrical and electronic equipment must not be disposed of with normal household wa...