Pulsar PSBSEP04124 Manual Download Page 9

www.pulsar.pl

    

 

 

 

PSBSEP04124  

 

 

 

 
 

 

                         Diagram of connecting the camera and the recorder to the MSEP412 module. 

 

 

 

 

 
3. Power supply operation indication. 
 

3.1  Optical indication. 
 

The PSU is fitted with 8 LED lights at the front panel:

 

 

 

 

 
RED LED: 

 

on – The PSU supplied with 230V AC voltage 

 

off – no 230V AC mains supply 

RED LED: 

 

on – low battery voltage V

BAT

 <23V 

 

off – battery voltage OK 

RED LED: 

 

on – battery failure 

 

off – no failure 

YELLOW LED: 

 

on – battery charging 

 

off – no battery charging 

 

 
GREEN LED: 

 

on – DC voltage at the AUX1 ÷ AUX4 outputs 

 

off – no DC voltage at the AUX1 ÷ AUX4 outputs 

 

 

Additionally, the PSU is fitted with LEDs on the PCB – see Fig. 2: 
AC red LED (Fig. 2, component 14) – is permanently illuminated during normal operation (AC power ON).  
No AC power is indicated by turning off the LED. 
FPS red LED (Fig. 2, component 5) is not illuminated during normal operation (no failure). In case of activation of 
the short circuit / overload protection at any output, the LED is permanently illuminated.  
AUX1 ÷ AUX4 green LEDs (Fig. 2, component 5) indicate voltage at the individual outputs of the module (L1 for 
AUX 1 etc.). Activation of the short circuit / overload protection of a given circuit is indicated by turning off one of 
the Lx LEDs.  
FLB red LED (Fig.2, component 5) – indicates battery voltage. During normal operation (UBAT > 23V), it is 
permanently illuminated. In case of battery voltage drop (UBAT < 23V) the LED is off. 
LB yellow LED (Fig. 2, component 4) – indicates battery charging. The LED goes out at the end of the charging 
process. 
 

Summary of Contents for PSBSEP04124

Page 1: ...PSBSEP04124 v 1 1 PSBSEP 12 18V 4x1A 2x7Ah SEP Switch mode buffer power supply unit for CCTV EN Edition 3 from 12 12 2013 Supercedes the edition 2 from 16 09 2013...

Page 2: ...tion Antisabotage protection warranty 5 years from the production date CONTENTS 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of components and connectors of the PS...

Page 3: ...unit will instantly switch to battery operation The PSU is enclosed in a metal casing color RAL 9003 with battery housing for two 7Ah 12V batteries The enclosure is fitted with a microswitch indicatin...

Page 4: ...U status OC type open collector hi Z state failure L state correct operation FLB technical output indicating low battery level OC type open collector hi Z state failure L state current operation 7 Jum...

Page 5: ...f the PSU see Fig 3 Component No Fig 3 Description 1 Isolation transformer 2 FMAIN fuse in the power supply circuit 230V AC 3 L N power connector 230V AC Protection connector PE 4 Connectors for conne...

Page 6: ...reverse polarity connection 4A current limitation FBAT fuse failure requires fuse replacement Deep discharge battery protection UVP 20 0 V 5 disconnecting the battery terminal Surge protection 4 x var...

Page 7: ...rging 2 Output current 4 x 1A 0 5A battery charging Total current of the receivers battery is max 4 5A The maximum output current is set to 4x1A at the output voltage of 12V If the output voltage is h...

Page 8: ...itch on the 230V AC power to the transformer AC LED should be permanently illuminated AUX LED should be permanently illuminated 9 Use the VADJ potentiometer to set the required output voltage of indiv...

Page 9: ...nt 14 is permanently illuminated during normal operation AC power ON No AC power is indicated by turning off the LED FPS red LED Fig 2 component 5 is not illuminated during normal operation no failure...

Page 10: ...ts Fig 6 Electrical diagram of the relay output TAMPER output indicating enclosure opening volt free contact input indicating the status of the power supply doors PSU closed contacts closed NC PSU ope...

Page 11: ...otection UVP configured with the PBAT jumper The battery protection is on when the PBAT jumper is off 4 5 Maintenance All maintenance procedures can be performed after disconnecting the power supply f...

Page 12: ...ue to the breaking warranty terms by the claimant 7 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer exclusively 8 The warranty does not cov...

Reviews: