The shock protection circuit shall be performed with a particular care, i.e. the yellow and 
green wire coat of the power cable shall stick to one side of the ‘PE’ terminal. Using the PSU 
without a properly made and fully operational shock protection circuit is UNACCEPTABLE! 
It can cause a device failure or an electric shock. 
 

 

 

4. Connect load/loads to proper output connectors of the power supply (positive pole is marked as +V, 
negative pole as -V) 
5. Connect the technical outputs to the central or other device. 
6. Connect the battery in accordance with the signs (colours). 
7. Once the tests and operation control have been completed, the enclosure/cabinet can be locked. 

 

 

Fig 3. Mechanical view of the PSU. 

 

3. Operating status indication. 

 

3.1 LED indication 

 

The PSU is equipped with 3 LEDs on the PCB board:

 

 - red LED (Fig.2, element 1) normal status (AC power): permanently illuminated. AC power absence is 
indicated by the AC diode going out.  

 

-  green  LED  (Fig.2,  element  2)  indicates  DC  power  at  the  PSU  output.  Under  normal  status  the  diode  is 
permanently illuminated. In case of a short circuit or an overload, the diode is off. 
 
- green LED  (Fig.2, element 3) indicates battery voltage level. Under normal status (U

BAT

 > 23V) the diode is 

permanently illuminated. In case of decrease of battery voltage (U

BAT

 < 23V) the diode is off.

 

Summary of Contents for PSBOC502418

Page 1: ...PSBOC502418 v 1 1 PSBOC 27 6V 1 8A OC Enclosed buffer switch mode power supply unit with technical outputs EN Edition 9 from 01 03 2018 Supercedes edition 8 from 01 06 2016...

Page 2: ...S 1 Technical description 1 1 General description 1 2 Block diagram 1 3 Description of PSU components and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Ope...

Page 3: ...sence technical output relay type 5 PSU output indicating DC absence PSU failure relay type 6 LoB output indicating battery low voltage relay type 7 EPS AC absence technical output OC type 8 PSU outpu...

Page 4: ...oad protection OLP 105 150 of power supply automatic recovery Battery circuit protection SCP and reverse polarity connection polymer fuse Surge protection varistors Surge over voltage protection OVP 3...

Page 5: ...able Vibrations and impulse waves during transport PN 83 T 42106 2 Installation 2 1 Requirements The buffer PSU is to be mounted by a qualified installer holding relevant permits and licenses applicab...

Page 6: ...ccordance with the signs colours 7 Once the tests and operation control have been completed the enclosure cabinet can be locked Fig 3 Mechanical view of the PSU 3 Operating status indication 3 1 LED i...

Page 7: ...el 0V In case of decrease of battery voltage UBAT 23V the output is switched into high impedance state hi Z relay output In case of a battery voltage drop UBAT 23V the contacts of the relay change ove...

Page 8: ...e and to collect such WEEE separately The power supply unit is adapted for a sealed lead acid battery SLA After the operation period it must not be disposed of but recycled according to the applicable...

Reviews: