Pulsar PSAC 04244 Manual Download Page 8

www.pulsar.pl 

PSAC04244 

   

 

 

4. Operation and use. 

4.1 Overload or short circuit at the PSU output 

The AUX1

÷AUX4 PSU outputs are protected against a short circuit with glass or polymer fuses. In case of fuse 

damage, the replacement of the same parameters is required. 

  
If the polymer fuse-assisted protection has been chosen, there will be an automatic disconnection of the output 

voltage indicated by the green diode going out. Then, cut off the load from the PSU output for approx. 1 minute.  

If the PSU is loaded with current exceeding 

Σ4,0A@24V AC (110%for ÷ 150% of S power), there occurs the F 

fuse damage in the 230

V AC circuit and/or F1÷F4 fuses. In case of a failure, replace the fuse of the same parameters. 

 

4.2 Maintenance. 

Any and all maintenance operations may be performed following the disconnection of the PSU from the power 

supply  network.  The  PSU  does  not  require  performing  any  specific  maintenance  measures.  However,  in  case  of  a 
significant  dust  level,  clean  the  interior  with  compressed  air.  In  case  of  a  fuse  replacement,  use  one  of  the  same 
parameters.  

 

 
 

WEEE MARK 

 

According  to  the  EU  WEE  Directive  –  It  is  required  not  to  dispose  of  electric  or  electronic 
waste as unsorted municipal waste and to collect such WEEE separately. 

 

 

 
 
 
 
 
 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

GENERAL WARRANTY CONDITIONS 

 

1. Pulsar (the manufacturer) grants a five-year warranty for the equipment, counted f

rom the device’s production date. 

 2. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 
defects have been reported within the warranty period (item 1).  
3. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  
4. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   
5. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, however not 
later that within 14 days from the delivery to the service centre of the manufacturer.  
6. The repair period mentioned in item 5 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
7. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  
8. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 

use that violates the operation manual or equipment’s intended use 

- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  
- improper installation and configuration (in defiance with the manual), 
9. The warranty is void in any of the following circumstances: 
- construction changes  
- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 
- modifications of the serial number 
10. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase.  
11. The manufacturer takes no responsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the 
recommendations and requirements contained in the manual, or the use of the equipment.  

Pulsar  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

www.zasilacze.pl

 

 

 

Summary of Contents for PSAC 04244

Page 1: ...PSAC 04244 v 1 1 PSAC 24VAC 4A 4x1A AC power supply for up to 4 analog cameras EN Edition 5 from 25 05 2015 Supersedes the edition 4 from 05 11 2014...

Page 2: ...mponents and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication 3 2 Technical outputs 4 Operation and use 4 1 Ove...

Page 3: ...wer input 4 AUX1 AUX4 outputs joint terminal COM 5 LFPS red LED indicating failure at one of the outputs fuse activation 6 FPS output indicating failure at one of the outputs OC type L normal state hi...

Page 4: ...s of the PSAC 04244 power supply unit Element no Fig 4 Description 1 Isolation transformer 2 Fuse strip module LB4 24V 27V AW tab 1 3 TAMPER tampering connector NC 4 F fuse in the power supply circuit...

Page 5: ...al specifications tab 3 Mains supply 230V AC 15 10 Current consumption 0 5 A max Power frequency 50 Hz Power of the S PSU 100VA max Output voltage U1 23 28V AC 100 load 0 load U2 25 5 31 5V AC 100 loa...

Page 6: ...P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit a...

Page 7: ...U2 jumpers Adjustment in the output voltage value 24V AC 27V AC is independent for each AUX output 7 Restore the mains power 230 V AC 8 Check the LED indication for PSU operating status LEDs L1 L4 gre...

Page 8: ...arranty applies to complete equipment accompanied by a properly filled warranty claim with a description of the defect 5 Should the claim be accepted the manufacturer is obliged to provide warranty re...

Reviews: