Pulsar PSAC 04244 Manual Download Page 2

www.pulsar.pl 

PSAC04244 

   

 

 

Features: 

 

  the 4x 1A/24V AC or 27V AC power output for 

    powering analog cameras

 

  power voltage 230V AC 

  4 outputs protected independently by 1A fuses 

  jumper selectable fuse type: glass fuse or 

    polymer fuse 

  LED indication 

 

FPS technical output indicating failure 

 

protections: 

 

SCP short-circuit protection 

 

OLP overload protection 

 

OHP overheat protection 

 

surge protection 

 

against tampering 

 

warranty 

– 5 year from the production date 

 

 

An example of  power supply for analog cameras. 

 

range

 24V or

 

27V AC, 4 x 1A

 

CONTENTS: 
1. Technical description. 

1.1 General description 
1.2 Block diagram 
1.3 Description of PSU components and connectors 
1.4 Specifications 

2. Installation. 

2.1 Requirements 
2.2 Installation procedure 

3. Operating status indication. 

3.1 LED indication  
3.2 Technical outputs

 

4. Operation and use. 
 

4.1. Overload or short circuit at the PSU output 

 

4.2. Maintenance 

 

 
1. Technical description. 
 

1.1. General description. 

The  AC/AC 

PSAC  04244

 

power  supply  is  designed  to  supply  analog  cameras  or  other  devices  requiring 

stabilized  voltage  of 

24V  AC  or  27V  AC 

and  total  capacity  of 

4A@24V  AC  24V  AC  or  27V  AC 

and  total  capacity  of 

4A@24V  AC. 

It  features  4  outputs  protected  independently  with  glass  or  polymer  fuses.  Output  voltage  range  is  step-

adjustable by appropriate jumpers, independently for each AUX output.  The PSU is housed in a metallic enclosure that 
features a microswitch indicating unwanted opening of the front door (faceplate). 

 
 

 

Summary of Contents for PSAC 04244

Page 1: ...PSAC 04244 v 1 1 PSAC 24VAC 4A 4x1A AC power supply for up to 4 analog cameras EN Edition 5 from 25 05 2015 Supersedes the edition 4 from 05 11 2014...

Page 2: ...mponents and connectors 1 4 Specifications 2 Installation 2 1 Requirements 2 2 Installation procedure 3 Operating status indication 3 1 LED indication 3 2 Technical outputs 4 Operation and use 4 1 Ove...

Page 3: ...wer input 4 AUX1 AUX4 outputs joint terminal COM 5 LFPS red LED indicating failure at one of the outputs fuse activation 6 FPS output indicating failure at one of the outputs OC type L normal state hi...

Page 4: ...s of the PSAC 04244 power supply unit Element no Fig 4 Description 1 Isolation transformer 2 Fuse strip module LB4 24V 27V AW tab 1 3 TAMPER tampering connector NC 4 F fuse in the power supply circuit...

Page 5: ...al specifications tab 3 Mains supply 230V AC 15 10 Current consumption 0 5 A max Power frequency 50 Hz Power of the S PSU 100VA max Output voltage U1 23 28V AC 100 load 0 load U2 25 5 31 5V AC 100 loa...

Page 6: ...P between input circuit and PE protection circuit I P FG between output circuit and PE protection circuit O P FG 3000 V AC min 1500 V AC min 500 V AC min Insulation resistance between input circuit a...

Page 7: ...U2 jumpers Adjustment in the output voltage value 24V AC 27V AC is independent for each AUX output 7 Restore the mains power 230 V AC 8 Check the LED indication for PSU operating status LEDs L1 L4 gre...

Page 8: ...arranty applies to complete equipment accompanied by a properly filled warranty claim with a description of the defect 5 Should the claim be accepted the manufacturer is obliged to provide warranty re...