Pulsar POE1648C Manual Download Page 6

www.pulsar.pl                                                      POE1648C   

 

 

 

 

Diagram 1. Maximum permissible output current depending on ambient temperature. 

 
2.  Installation. 

 

2.1.  Requirements. 

   The  buffer  PSU should  be  mounted  by  a  qualified installer,  holding  relevant  permits  and  licenses  (applicable 

and    required   for    a   given   country)   for    230V/AC    and    low-voltage   installations.  The    unit   should    be  mounted    in  
confined    spaces,    in    accordance    with    the    2nd  environmental    class,    with    normal    relative    humidity  (RH=90% 
maximum, no condensation) and temperature range from -

10°C up to +40°C. The  power  supply  should  operate  in  a  

vertical position in order to provide free and  convectional  air  flow  through ventilating holes of the enclosure.  

 
 
             During normal operation, the total current drawn by the device should not exceed I=16x0,3A

*

Maximum battery charging current is 0,5A. Total current of the receivers  + battery is max 5A*. 
 

              The  power  supply  is  designed  for  a  continuous  operation  and  is  not  equipped  with  a  power-switch. 
Therefore, an appropriate overload protection in the power supply circuit should be provided. Moreover, the user should 
be informed how to disconnect the power supply unit from the mains supply (usually by assigning an appropriate fuse in 
the fuse box).   The electrical system shall be made in accordance with applicable standards and regulations.  

 
The  PSU  is  designed  for  10Mbit/s  and  100Mbit/s  Ethernet  network  (so-called  Fast  Ethernet)

.  However,  it  can 

not be used for a 1000 Mbit/s network (so-called Gigabit Ethernet).

 Connections between the power supply and the 

camera  can  be  done  using  UTP-3  cable  (networks  with  data-rates  up  to  10  Mbit/s)  or  UTP-5  cable.  Due  to  the  lower 
resistance wiring, it is recommended (especially at large distances between the power supply and receivers) to use UTP-
5 cable also for networks with data-rates up to 10 Mbit/s.  

 

2.2. Installation procedure. 

1. Before installation, cut off the voltage in the 230V power-supply circuit. 

2. Mount the PSU in a selected location and lead the connecting cables.  
3.  Connect  the  power  cables  (230V  AC)  to  L-N  terminals  of  the  PSU.  Connect  the ground  wire  to  the  terminal  marked 

with grounding symbol:

. Use a three-core cable (with a yellow and green PE protection wire) to make the connection. 

The power cables should be connected to the appropriate terminals on the connection board through the bushing.  

 

 

The shock protection circuit shall be done with a particular care: the yellow and green wire 

coat of  the  power  cable  should be connected to  the  terminal  marked  with  the  

  symbol  

in  the  PSU enclosure. Operation of the PSU without the properly made and fully operational 
shock  protection  circuit  is  UNACCEPTABLE!  It  can  cause  damage  to  the  equipment  or  an 
electric shock

 

 
4. Connect the network cables (Ethernet) to the PoE module: supply voltage is present only at the POE sockets and the 
cameras should be connected to them. Pin assignment of the LAN and POE sockets is shown in the Figure 4: 
 

                                                 

*

 

See diagram 1

 

Summary of Contents for POE1648C

Page 1: ...POE1648C v 1 0 PoE 54V 5A 4x17Ah PoE buffer power supplyfor up to 16 IP cameras EN Edition 2 from 22 11 2016 Supersedes the edition 1 from 12 02 2016...

Page 2: ...ion protections SCP short circuit protection OVP overvoltage protection Surge protection Antisabotage protection OLP overload protection warranty 2 year from the production date An example of power su...

Page 3: ...transmission uses 1 2 and 3 6 data pairs The PSU can not be used in Gigabit Ethernet networks where all twisted pairs are involved in the transmission of data During normal operation the total curren...

Page 4: ...dicating correct operation of the switch mode PSU 4 ADJ potentiometer regulation of the power supply output voltage 5 PoE module 6 Connectors for connecting the batteries BAT red BAT black 7 TAMPER mi...

Page 5: ...YES LED lights Mechanical parameters Table 4 Enclosure dimensions 420 x 373 x 181 14 mm WxHxD Mounting See Fig 3 Battery housing 4x17Ah 12V SLA max 415x170x170mm WxHxD max Net weight 7 70kg 8 30kg Enc...

Page 6: ...twork so called Fast Ethernet However it can not be used for a 1000 Mbit s network so called Gigabit Ethernet Connections between the power supply and the camera can be done using UTP 3 cable networks...

Page 7: ...overload the output voltage is automatically shut off and so is the LED indicator The restoration of the voltage takes place immediately after the failure overload is over 4 2 Battery operation In ca...

Page 8: ...ment should be disposed of separately from normal household waste CAUTION The power supply unit is adapted for cooperation with the sealed lead acid batteries SLA After the operation period they must...