Pulsar POE1648C Manual Download Page 4

www.pulsar.pl                                                      POE1648C   

 

 

 

 

Fig. 2. Components arrangement. 

 

 

Fig. 3. The view of the PSU. 

 
 

 

Component No. 

[Fig. 3] 

Description 

[1] 

The module of the switch mode PSU 

[2] 

L-N  

power-supply connector 230V AC, 

 

PE

 protection connector 

[3] 

LED light indicating correct operation of the switch mode PSU 

[4] 

ADJ

 potentiometer 

– regulation of the power supply output voltage 

[5] 

PoE module 

[6] 

Connectors for connecting the batteries: +BAT = red, - BAT = black 

[7] 

TAMPER 

– microswitch (contacts) of antisabotage protection

 (NC)

 

Tab. 2. Components of the PSU (see Fig. 3). 

 
 
 
 

 

1.4 Technical parameters. 

   - electrical parameters (Table 3) 
   - mechanical parameters (Table 4) 
   - safety of use (Table 5) 
   - operation parameters (Table 6) 
 
 

Summary of Contents for POE1648C

Page 1: ...POE1648C v 1 0 PoE 54V 5A 4x17Ah PoE buffer power supplyfor up to 16 IP cameras EN Edition 2 from 22 11 2016 Supersedes the edition 1 from 12 02 2016...

Page 2: ...ion protections SCP short circuit protection OVP overvoltage protection Surge protection Antisabotage protection OLP overload protection warranty 2 year from the production date An example of power su...

Page 3: ...transmission uses 1 2 and 3 6 data pairs The PSU can not be used in Gigabit Ethernet networks where all twisted pairs are involved in the transmission of data During normal operation the total curren...

Page 4: ...dicating correct operation of the switch mode PSU 4 ADJ potentiometer regulation of the power supply output voltage 5 PoE module 6 Connectors for connecting the batteries BAT red BAT black 7 TAMPER mi...

Page 5: ...YES LED lights Mechanical parameters Table 4 Enclosure dimensions 420 x 373 x 181 14 mm WxHxD Mounting See Fig 3 Battery housing 4x17Ah 12V SLA max 415x170x170mm WxHxD max Net weight 7 70kg 8 30kg Enc...

Page 6: ...twork so called Fast Ethernet However it can not be used for a 1000 Mbit s network so called Gigabit Ethernet Connections between the power supply and the camera can be done using UTP 3 cable networks...

Page 7: ...overload the output voltage is automatically shut off and so is the LED indicator The restoration of the voltage takes place immediately after the failure overload is over 4 2 Battery operation In ca...

Page 8: ...ment should be disposed of separately from normal household waste CAUTION The power supply unit is adapted for cooperation with the sealed lead acid batteries SLA After the operation period they must...

Reviews: