GREEN POWER CCTV PoE

 

 

 

Additionally, the PSU is fitted with LED lights inside the enclosure – see Fig. 2 and 3: 
L

AC

 red LED (Fig. 2, component 1) is permanently illuminated during normal operation (AC power ON).  

No AC power is indicated by turning off the L

AC 

LED. 

L

IN

 green LED (Fig. 2, component 1) indicates DC voltage at the PoE module input. During normal operation (DC 

supply) the LED is permanently illuminated. No DC no DC voltage at the module input is indicated by turning off the 
L

IN 

LED.  

L

FPS

 red LED (Fig. 2, component 10) is not illuminated during normal operation (no failure). In case of activation of 

the short circuit / overload protection at any output, the LED is permanently illuminated.  
L1 ÷ L4 green LEDs (Fig. 2, component 5) indicate voltage at the individual outputs of the module (L1 for AUX 1 
etc.). Activation of the short circuit / overload protection of a given circuit is indicated by turning off one of the Lx  
LEDs.  
 

3.1. Technical outputs. 

 

The PSU has the following indication outputs: 

  FPS – technical output of the PSU status:  

-  OC  type  output  indicating  failure  (short-circuit,  overload).  During  normal  operation,  shorted  to  ground  –  L 
state (0V). In case of power loss, the FPS technical output is switched into hi-Z state (high impedance) at least 
at one of the AUX outputs. 
 

 

 

Fig. 5. Electrical diagram of the OC output. 

 
- relay output. In case of failure, relay contacts are switched automatically. 
 

 

 

Fig. 6. Electrical diagram of the relay output 

 

 

CAUTION! The arrangement of contacts at the figure 6 shows a potential-free status of the relay, 
which is equivalent to a state with no voltage at any of the AUX1 ÷ AUX4 outputs. 

 

 

  TAMPER – output indicating enclosure opening: - volt free contact input indicating the status of the 

power supply doors, PSU closed: contacts closed (NC), PSU open: contacts open (NO). 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for POE042418B

Page 1: ...POE042418B v 1 0 PoE 27 6V 4x0 4A 2x7Ah Switch mode buffer power supply unit for CCTV EN Edition 1 from 09 01 2014 Supersedes the edition GREEN POWER CCTV PoE...

Page 2: ...Maintenance 1 Technical description 1 1 General description The PSU is designed for supply of up to 4 webcams requiring stabilized voltage of 24V DC 15 The PSU supplies voltage of 27 6V DC and total c...

Page 3: ...ns supply indication input 3 F1 F4 fuses in the AUX1 AUX4 F500mA circuits 4 Jumper to select melting fuse or PTC polymer fuse 5 Green LED L1 L4 voltage indication at the AUX outputs during normal oper...

Page 4: ...he module of the switch mode PSU 2 LED light indicating correct operation of the switch mode PSU 3 V1 ADJ potentiometer regulation of the power supply output voltage 4 PoE module 5 Connectors for conn...

Page 5: ...protection 4 x varistor Antisabotage protection TAMPER output indicating enclosure opening microswitch NC contacts enclosure closed 0 5A 50V DC max Optical indication of operation YES LED lights Techn...

Page 6: ...imum battery charging current is 0 2A Total current of the receivers battery is max 1 8A The power supply is designed for a continuous operation and is not equipped with a power switch Therefore an ap...

Page 7: ...position melting fuse activation PTCx PTC fuse activation 6 If needed the following technical connections can be made FPS technical output of the PSU status indicates the voltage loss at any of the ou...

Page 8: ...odule L1 for AUX 1 etc Activation of the short circuit overload protection of a given circuit is indicated by turning off one of the Lx LEDs 3 1 Technical outputs The PSU has the following indication...

Page 9: ...fuse In case of melting fuse activation it should be replaced with a fuse of the same type and of the same rated current 4 2 Battery operation In case of mains power loss the unit will instantly swit...

Page 10: ...service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...

Reviews: