![Pulsar PG4500BiSRCO Operator'S Manual Download Page 21](http://html1.mh-extra.com/html/pulsar/pg4500bisrco/pg4500bisrco_operators-manual_1624634021.webp)
21
MAINTENANCE
Air Filter
A dirty air filter will reduce the life span of the engine, make it difficult to start the engine, and reduce
the unit's performance. Replace with new Air Filter annually.
•
To clean, remove the screws then remove left outer casing
•
Turn the spring latches to lift then open air filter cover.
•
Remove the pleated paper filter
•
Blow the dust away with a compressed air
•
Reinsert the pleated paper filter into the air filter case.
Do not run the generator without reinstalling the foam element or excessive piston and
CAUTION!
cylinder wear may result
, or excessive engine wear may result
.
•
• Allow hot components to cool before touching.
WARNING!
Avoid contacting hot areas of this
generator
.
4
6
Order of removal
•
Inspect muffler for cracks, corrosion, or other damage.
•
Remove screws, then remove the muffler cover as shown.
•
Remove the cover, then remove muffler cap, muffler screen, and spark
arrester.
•
Check the muffler screen and spark arrester for carbon deposits.
Remove carbon deposits with a wire brush.
•
Check the muffler screen and spark arrester for damage. If damaged
replace with PULSAR replacement parts specifically designed for this
unit.
•
Install the spark arrester.
•
Align the spark arrester insert with the hole in the muffler pipe.
•
Install the muffler screen and rear grille.
•
Install the outer casing and tighten the screws.
1
5
3
2
Summary of Contents for PG4500BiSRCO
Page 25: ...WIRING DIAGRAM 25 M θ θ ...