10
CONTROL PANEL FUNCTIONS
Note: The economy switch must be moved to the “OFF” position when using electrical devices that require a large starting
current, such as an air compressor.
Parallel Connections
Located just above the Ground Terminal, the generator’s Parallel Connections enable a user to run two P
G
4500
B
iSR
CO
generators simultaneously. This feature requires special cables and a parallel kit. When operating generators in parallel,
the rated output is 7.4kVA and the rated output is 61.6A/120VAC. To operate generators in parallel consult a PULSAR
dealer for a PARALLEL OPERATION CABLE KIT
• Only connect this generator to another
PG4500BiSRCO
Inverter Generator.
• Only use a parallel operation cable kit designed to work with this Generator.
WARNING!
Never connect generators that are different models.
• When the engine economy switch is in the “ON” position, the economy control unit automatically determines the
generator’s proper engine speed based on the connected electrical load
.
This results in superior fuel economy
and reduces noise.
• When the economy switch is in the “OFF” position, the engine will maintain a nominal speed of of 3,100 r/min.
A
C Circuit Breaker
When the
A
C Circuit Breaker is in the “I” position, the generator is able to supply power to connected electrical devices.
When the
A
C Circuit Breaker shifts to the "O" position, the generator will no longer supply power. The
A
C Circuit
Breaker automatically shifts to the "O" position when connecting electrical devices to the generator that exceed the
generator’s rated
A
C output. If the
A
C Circuit Breaker shifts to the "O" position , reduce the load of connected electrical
device until the load is within rated
A
C output. To re-establish power, shift breaker to the "I" position.
Engine Economy Control
Fuel
Tank
Cap
Turn counterclockwise to remove the fuel
tank
cap.
Grounding the Generator
This portable inverter generator is equipped with a terminal for the connection of a
ground electrode conductor where a grounding electrode system is required by NEC
Article 250.34(A). The equipment grounding conductors of the generator receptacles
are bonded
to the generator frame. Where the generator supplies power to cord and
plug connected equipment, like power tools, the frame of the generator is not required
by the NEC to be connected to an earthen ground electrode. The generator neutral
conductor is
bonded
to th
e generator frame in accordance with NEC Article 250.34(C)