Pulsar PG3250 Operator'S Manual Download Page 21

TROUBLESHOOTING

2

1

Problem

Cause

Solution

Engine is running, but AC output is not 

available

1. Open circuit breaker

2. Poor connection

3. Defective cord set

4. Connected device is faulty

5. Fault in generator

1. Reset circuit breaker

2. Check and repair

3. Check and repair

4. Connect a device that is working

properly

5. Contact service department

Engine runs well without load but bogs 

down when loads are connected

1. Short circuit in connected device

2. Generator is overloaded

3. Clogged fuel filter

4. Engine speed is too slow

5. Short circuit in generator

1. Disconnect device

2. See pg 17 “Don’t overload

generator”

4. Contact service department

3. Clean or replace fuel filter

5. Contact service department

Engine will not start, shuts down during 

operation, or starts and runs rough.

1. ON/OFF switch set to “OFF”

2. Dirty Air filter

3. Clogged fuel filter

4. Stale fuel

5. Spark plug wire disconnected from

spark plug

6. Bad spark plug

7. Water in fuel

8. Fuel valve is in “OFF” position

9. Over choking

10. Low oil level

11. Rich fuel mixture

12. Intake valve stuck open or closed

13. Loss of engine compression

14. Dead battery

15. Engine has flooded

1. Turn switch to “ON”

2. Replace Air filter

3. Clean or replace fuel filter

4. Replace fuel

5. Reconnect spark plug wire

6. Replace spark plug

7. Drain fuel tank and replace fuel

8. Turn fuel valve to “ON” position

9. Turn off choke

10. Fill crankcase to proper oil level &

place generator on a level surface

11. Contact service department

12. Contact service department

13. Contact service department

14. Recharge or replace battery

15. Wait 5 minutes and recrank engine

Engine lacks power

1. Generator is overloaded

2. Clogged fuel filter

3. Dirty Air filter

4. Engine needs servicing

1. See pg 17 “Don’t overload

2. Clean or replace fuel filter

3. Replace Air filter

generator”

4. Contact service department

Engine “hunts” or falters

1. Choke was removed too soon

2. Clogged fuel filter

3. Carburetor is running too rich or too

1. Move choke to middle position until

2. Clean or replace fuel filter

engine runs evenly

3. Contact service department

lean

Summary of Contents for PG3250

Page 1: ...Generator Model PG3250 www pulsar products com OPERATOR S MANUAL...

Page 2: ...Connecting Generator to an Electrical System 10 Operation 11 How to Start Engine 11 Grounding the Generator 11 How to Stop Engine 12 Receptacles and Extension Cords 13 Don t Overload Generator 14 Wat...

Page 3: ...order parts receive warranty assistance or other services inquiries you can contact us by internet at www pulsar products com or write to us at The emissions control system for this generator is compl...

Page 4: ...serious injury avoid attempting to lift the generator alone WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cau...

Page 5: ...If unit has been running then the fuel cap is under pressure remove slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the...

Page 6: ...will supply the correct rated frequency and voltage WARNING Never modify this unit in any way or modify governed speed Never handle the generator electronic devices or any cord while standing in wate...

Page 7: ...FEATURES A B C 7 A ON OFF Start Switch B 1 12V DC Output For Charging Batteries Only C 2 120V Receptacles D Circuit Protector E Oil Alert F Grounding Connection D E F...

Page 8: ...8 FEATURES K G L J G Fuel Tank Vapor Vent H Choke Level I Fuel Valve ON OFF I H J Recoil Starter Grip K Air Filter L Fuel Tank...

Page 9: ...kcase dipstick to ensure you do not overfill the engine Insert a funnel into the crankcase dipstick hold and carefully add 4 Cycle engine oil SAE10W 30 to empty reservoir until oil reaches the outer e...

Page 10: ...serious injury or death to electric utility workers WARNING This generator produces a very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator...

Page 11: ...wards engine faster than you can let go which could result in injury Always start the engine and let it stabilize before connecting any electronic devices Disconnect all electronic devices before stop...

Page 12: ...ver start or stop the engine with electrical devices plugged in to the receptacles Turn the fuel valve to the OFF position Turn the engine ON OFF switch to the OFF position Fig 11 Fig 12 Fig 13 2 Fig...

Page 13: ...RATION Do not connect 3 phase loads to generator CAUTION 12 Volt 8 3 Amp Output is for charging batteries only WARNING 13 This receptacle has a 13 A main circuit breaker to protect against overload Ex...

Page 14: ...our back to avoid injury Don t Overload Generator Make sure you can supply enough rated watts and surge watts for all electronic devices connected to the generator Rated watts refer to the power a gen...

Page 15: ...0 2200 Furnace Fan HP 800 2350 Sump Pump HP 1000 2000 Water Pump HP 1000 3000 Heating Cooling 650 800 Table Fan Dehumidifier 800 2000 Window AC 10k BTU 1200 3600 Central Air 10k BTU 1500 6000 Electric...

Page 16: ...section of manual 5 Shelter unit from elements OPERATION 16 High Altitude Operation At high altitude the standard carburetor air fuel mixture will be too rich Performance will decrease and fuel consu...

Page 17: ...sure the air filter is clean Remove any debris that has collected on the generator and around the muffler and controls Use a vacuum cleaner to pick up loose debris If dirt is caked on use a soft bris...

Page 18: ...inage plug and allow oil to drain completely Reinstall oil drainage plug tighten securely To clean remove the air filter cover Carefully pull the air filter out by lifting up along the edges Remove di...

Page 19: ...r shop Fuel tank must be empty before replacing fuel filter Run unit until tank is empty if needed or inspect filter prior to fill up CAUTION Spark Arrestor See Fig 18 If Appicable Inspect the spark a...

Page 20: ...ing you to access the petcock When the fuel has drained from the tank close the fuel valve and reinstall fuel line securely on petcock Reinstall the fuel valve knob in the valve bracket Push forward u...

Page 21: ...er in fuel 8 Fuel valve is in OFF position 9 Over choking 10 Low oil level 11 Rich fuel mixture 12 Intake valve stuck open or closed 13 Loss of engine compression 14 Dead battery 15 Engine has flooded...

Page 22: ...DIAGRAMS 22...

Page 23: ...tor engine and alternator components parts and labor Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including comm...

Page 24: ...the United States Canada or Mexico Refurbished used demonstration or floor models are not covered by this warranty Products purchased from on line auction websites such as ebay are not covered under...

Reviews: