![Pulsar PG3250 Operator'S Manual Download Page 13](http://html1.mh-extra.com/html/pulsar/pg3250/pg3250_operators-manual_1624759013.webp)
Receptacles and Extension Cords
Only use high quality, well-insulated, grounded extension cords in good condition with generator receptacles. Extension
cords should have a minimum rating of 125 Volts AC, 20 Amps and should be kept as short as possible to minimize voltage
drop. Follow each load manufacturer’s power rating recommendation when selecting receptacle and extension cord.
This generator is equipped with the following receptacles:
120 Volt AC, 20 Amp receptacle
• Two 120 Volt AC, 20 Amp receptacles.
• 12 Volt 8.3 Amp Output (For charging batteries only)
• This receptacle has a 20 Amp push-to reset circuit breaker to protect against overload.
OPERATION
Do not connect 3-phase loads to generator.
CAUTION!
12 Volt 8.3 Amp Output is for charging batteries only!
WARNING!
1
3
•
This receptacle has a
13 A main circuit breaker to protect against overload.
Extension Cord Selection
Refer to the below table to ensure the extension cord used has the capacity to carry the required load. If the size of the
cable is inadequate it can cause a voltage drop, which can damage the electrical device and cord.
Current
(Amps)
Load (Watts)
Maximum Cord Length
120V
240V
#8 Wire
#10 Wire
#12 Wire
#14 Wire
#16 Wire
2.5
300
600
X
1000 ft.
600 ft.
375 ft.
250 ft.
5
600
1200
X
500 ft.
300 ft.
200 ft.
125 ft.
7.5
900
1800
X
350 ft.
200 ft.
125 ft.
100 ft.
10
1200
2400
X
250 ft.
150 ft.
100 ft.
50 ft.
15
1800
3800
X
150 ft.
100 ft.
65 ft.
X
20
2400
4800
175 ft.
125 ft.
75 ft.
X
X
25
3000
6000
150 ft.
100 ft.
X
X
X
30
3600
7200
125 ft.
65 ft.
X
X
X