Pulsar MSRD 1024 Manual Download Page 8

www.pulsar.pl                                                                        MSRD1024                                                                        

 

 

 

 

WEEE MARK 

 
 

 

According  to  the  EU  WEE  Directive  –  It  is  required  not  to  dispose  of  electric  or 
electronic  waste  as  unsorted  municipal  waste  and  to  collect  such  WEEE  separately.

 

The power supply unit is adapted for a sealed lead-acid battery (SLA). After the operation period it must not be disposed 

of but recycled according to the applicable law.

 

 

 

 

 

 

GENERAL WARRANTY CONDITIONS 

 

1. Pulsar K. Bogusz Sp.j. (the manufacturer) grants a two-year warranty for the equipment, starting from the initial product date 
of purchase placed on the receipt.  
2. If a purchase proof is missing, a three-year warranty period is counted from the device’s production date.  
3. The warranty includes free-of-charge repair or replacement with an appropriate equivalent (the selection is at the 
manufacturer’s discretion) if the malfunction is due to the manufacturer, includes manufacturing or material defects, unless such 
defects have been reported within the warranty period (item 1 and 2).  
4. The equipment subject to warranty is to be brought to the place where it was purchased, or directly to the main office of the 
manufacturer.  
5. The warranty applies to complete equipment, accompanied by a properly filled warranty claim with a description of the defect.   
6. Should the claim be accepted, the manufacturer is obliged to provide warranty repairs, at the earliest convenience, however not 
later that within 14 days from the delivery to the service centre of the manufacturer.  
7. The repair period mentioned in item 6 may be prolonged, if there are no technical possibilities to carry out the repairs, or if the 
equipment has been conditionally accepted, due to the breaking warranty terms by the claimant.  
8. All the services rendered by force of the warranty are carried out at the service centre of the manufacturer, exclusively.  
9. The warranty does not cover the defects of the equipment, resulting from: 
- reasons beyond the manufacturer's control, 
- mechanical damage, 
- improper storage and transport, 
- use that violates the operation manual or equipment’s intended use 
- fortuitous events, including lightning discharges, power failures, fire, flood, high temperatures and chemical agents,  
- improper installation and configuration (in defiance with the manual), 
10. The warranty is void in any of the following circumstances: 
- construction changes  
- repairs carried out by any unauthorized service center 
- damage or removal of warranty labels 
- modifications of the serial number 
11. The liability of the manufacturer towards the buyer is limited to the value of the equipment, determined according to the 
wholesale prices suggested by the manufacturer on the day of purchase.  
12. The manufacturer takes no responsibility for the defects that result from:  
- the damaging, malfunctioning or inability to operate the equipment 
- defects that result from using the equipment outside its stated specifications and operating parameters failing to abide by the 
recommendations and requirements contained in the manual, or the use of the equipment.  

Pulsar K.Bogusz Sp.j.  

Siedlec 150,  32-744 Łapczyca, Poland 

Tel. (+48) 14-610-19-40, Fax. (+48) 14-610-19-50 

e-mail: 

[email protected]

[email protected]

 

http:// 

www.pulsar.pl

 

 

Summary of Contents for MSRD 1024

Page 1: ...MSRD 1024 v 1 0 MSRD 27 6V 1A Buffer switch mode power supply module EN Edition 1st 14th Mar 2012 Supercedes ...

Page 2: ...t 0 8A 0 2A battery charge 3 Output current 0 5A 0 5A battery charge Total current of the receivers battery 1A max In case of power failure a battery back up is activated immediately The battery charging current is preset to 0 2A Features Uninterrupted supply of 27 6VDC 1A supply voltage external transformer required 27 30VAC AWT5172430 AWT049 high efficiency 85 battery charging and maintenance co...

Page 3: ...n collector type FAC AC absence technical output normal status L level 0V failure status hi Z level indication time lag approx 10 sec GND joint terminal FPS technical output of the PSU failure OC type normal status L level 0V failure status hi Z level 4 IBAT pin battery charging current adjustment IBAT Ibat 0 2A IBAT Ibat 0 5A Caption jumper on jumper off 5 VADJ potentiometer DC voltage adjustment...

Page 4: ...ng time 20ms 40ms 12ms Izn Uac min Voltage adjustment range 24 0 V 28 V Ripple voltage 40mV p p max Current drawn by the PSU module systems 25 mA max Battery charging current 0 2A 0 5A IBAT jumper selectable Short circuit protection SCP 200 250 of PSU module power current limitation and or fuse damage in the battery circuit fuse element replacement required Overload protection OLP 110 150 25ºC 55º...

Page 5: ...unacceptable Direct insolation unacceptable Vibrations and impulse waves during transport PN 83 T 42106 2 Installation 2 1 Requirements The buffer PSUmodule is to be mounted by a qualified installer holding relevant permits and licenses applicable and required for a given country for 230V AC interference and low voltage installations The unit should be mounted in confined spaces in accordance with...

Page 6: ...n a DIN rail 3 Operating status indication 3 1 LED indication The PSU module is equipped with four diodes indicating operating status AC LB AUX FBAT AC red diode under normal status AC supply the diode is permanently illuminated The absence of AC supply is indicated by the AC diode going out AUX green diode indicates the DC supply status in the output of the PSU module Under normal status the diod...

Page 7: ...output requires the replacement of the fuse 4 2 Battery assisted operation In case of the main power outage the device is immediately switched into a battery assisted operation In order to run the PSU module from the battery only connect the BAT connectors in accordance with the signs BAT red to plus and BAT black to minus then press the START button on the main board and hold it for 5 seconds The...

Page 8: ...eriod mentioned in item 6 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally accepted due to the breaking warranty terms by the claimant 8 All the services rendered by force of the warranty are carried out at the service centre of the manufacturer exclusively 9 The warranty does not cover the defects of the equipment resulti...