background image

Visit: 

www.tester.co.uk / 

Call: 

01642 931 329

The image is blurry, 

with vertical stripes 

and uneven 

background.

The image is too 

dark.

Poor image quality / 

Detection range 

reduced. 

Calibration is required.

Brightness or contrast level 

is too low.

Problems described may arise in adverse weather conditions 

(snow, rain, fog etc.).

Carry out calibration according 

to Section 

“SENSOR CALIBRATION”.

Adjust brightness/contrast with 

the UP/DOWN buttons. 

Smartphone or tablet 

PC cannot be 

connected to the 

device. 

Password in the unit was 

changed.

Delete network and connect 

again inserting the password 

saved in the device. 

Smartphone or tablet 

PC cannot be 

connected to the 

device. 

Password in the unit was 

changed.

Delete network and connect 

again inserting the password 

saved in the device. 

No Wi-Fi signal or 

erratic signal.  

The unit is beyond reliable 
Wi-Fi range.
There are obstacles between 

the device and the signal 

receiver (i.e. concrete walls). 

Place the device in line-of-sight
of the Wi-Fi signal. 

There are too many Wi-Fi 

networks in the area where the 

scope is located which may 

cause signal interference. 

To ensure stable Wi-Fi 

performance, move the 

riflescope to an area with few 

or no Wi-Fi networks.

 

The device cannot 

be powered on 

with wireless remote 

control.

Remote control is not 

activated. 

Low battery.

Activate the remote control 

according to instructions.

Install a new CR2032 battery.

When using the 

scope at below zero 

temperatures the 

image quality is 

worse than at 

positive 

temperatures.

Because of variations in thermal conductivity, objects (surrounding 

environment, background) under observation become warm more 

quickly  at  above-zero  temperatures,  which  allows  higher 

temperature contrast and, thus, the quality of the image produced 

by a thermal imager will be better. 

At  low  operating  temperatures,  objects  under  observation 

(background)  normally  cool  down  to  roughly  identical 

temperatures, which leads to lower temperature contrast, and to 

image quality (precision) degradation. This is normal for thermal 

imaging device.

Follow the link to read FAQs on thermal vision 

http://www.pulsar-nv.com/support/faq/

 

Check

Corrective action

Problem

26

25

Color stripes appear 

on the display or 

images disappears. 

The device has accumulated 

static charge during 

operation. 

As soon as the impact of the 

static charge is over, the device 

may reboot automatically; 

alternatively please turn off and 

restart the device. 

Summary of Contents for Helion XP50

Page 1: ...To Order Visit www tester co uk Call 01642 931 329 HELION Thermal Imaging Scope HELION Thermal Imaging Scope ...

Page 2: ...Visit www tester co uk Call 01642 931 329 ...

Page 3: ...Advertencia el funcionamiento de este equipo en áreas residenciales podría causar radio interferencias Compatibilità elettromagnetica Questo prodotto è conforme alla norma europea EN 55032 2015 ClasseA Avvertenza l uso di questa apparecchiatura in un area residenziale può causare perturbazioni radioelettriche Электромагнитная совместимость Данный продукт соответствует требованиям европейского стан...

Page 4: ...rating time on Battery Pack at t 22 C h Degree of protection IP code IEC60529 Operating temperature range Dimensions mm inch Weight without battery kg oz Video recorder Video photo resolution pixel Video photo format Built in memory Built in memory capacity Wi Fi channel Frequency Standard Line of sight reception range m Microbolometer MODEL HELION SKU Type Resolution pixels Frame rate Hz Pixel si...

Page 5: ...rse weather conditions fog smog rain to see through obstacles hindering detection of targets branches tallgrass thick bushes etc HELION thermal imaging scopes do not require an external source of light and are not affected by bright light exposure HELION thermal imaging scopes are designed for various areas of application including night hunting observation trail orienteering rescue operations etc...

Page 6: ...ing Switch to photo mode Photo mode Take a photograph Switch to video mode Charging BUTTON M 6 5 C D E Charging base Battery Pack Charger 220V socket Pic 3 Lift the lever C of the charging base Remove the protective cover from the Battery Pack Install the Battery Pack into the charging base as shown in Pic 3 click the lever C Upon installation a green LED indicator D on the charging base will star...

Page 7: ...ldren SAFETY MEASURES EXTERNAL POWER SUPPLY 7 The device can be powered with an external power supply such as Power Bank 5V Connect the external power supply to the USB port 4 of the device Pic 1 on the flyleaf The device switches to operation from external power supply and the IPS5 Battery Pack will begin slowly charging The display will show the battery icon with charge level as a percentage If ...

Page 8: ... or four times 8 times in XP models as well as to return to the basic magnification To operate the step up digital zoom press successively the button DOWN 8 QUICK MENU FUNCTIONS 11 The Quick menu allows change of basic settings display brightness and contrast continuous digital zoom and stadiametric rangefinder Notes actual magnification is the product of the basic magnification value and continuo...

Page 9: ...our to high temperature Hot Red Red Monochrome Rainbow Ultramarine Violet Sepia Switch between the palette selected in the menu and the basic palette with a short press of the UP 10 button A In automatic mode the need for calibration is based on software algorithm Calibration starts automatically The user determines for himself the need for calibration based on the actual image status Manual silen...

Page 10: ...rmat the memory card Message Memory card formatting means that formatting is in progress Upon completion of formatting the message Formatting completed is shown If No is selected formatting is aborted and you return to the submenu Language Date Date setup Enter the submenu Date with a short press of the M button Date format is displayed as YYYY MM DD year month day Select the correct values for th...

Page 11: ...d method or to abort deletion G H I x 95 y 99 Reset Restore default settings Enter the Reset submenu with a short press of the M 9 button With a short press of the UP DOWN buttons select Yes to restore default settings or No to abort Confirm selection with a short press of the M button If Yes is selected display will show Return default settings and Yes and No options Select Yes to restore default...

Page 12: ...g recording time 5 12 in the format HH MM hours minutes Start video recording with a short press of the REC 7 button Upon start of video recording icon disappears and icon REC and recording timer in the format MM SS minutes seconds appear instead Pause and resume recording video with a short press of the REC button Stop recording video with a long press of the REC button Video files are saved to t...

Page 13: ...t 0 7 m Deer height 1 7 m 160m 66m 28m icon icon icon icon 20 19 Notes you can enter and operate the menu during video recording recorded videos and photos are saved to the built in memory card in the format img_xxx jpg photos video_xxx avi videos xxx three digit counter for videos and photos counter for multimedia files cannot be reset Attention Maximum duration of a recorded file is seven minute...

Page 14: ...the M button USB connection Use as power Use as memory card 22 21 Move the lower fixed bar under the object being ranged and while pressing the UP DOWN buttons move the upper horizontal bar relative to the lower fixed bar until the object fits entirely between the two cursors The distance to the object is automatically recalculated as you move the upper line If ranging does not take place within 1...

Page 15: ...USB cable is damaged Charge the battery Replace USB cable Check Corrective action Problem External power supply is discharged Charge the external power supply if necessary 23 24 Connection modes Memory card external memory In this mode the device is detected by the computer as a flash card This mode is designed for work with the files saved in device s memory The device s functions are not availab...

Page 16: ...nsure stable Wi Fi performance move the riflescope to an area with few or no Wi Fi networks The device cannot be powered on with wireless remote control Remote control is not activated Low battery Activate the remote control according to instructions Install a new CR2032 battery When using the scope at below zero temperatures the image quality is worse than at positive temperatures Because of vari...

Page 17: ...Visit www tester co uk Call 01642 931 329 To order Pulsar Helion XQ28F Thermal Monocular Scope Call 01642 931 329 or Visit www tester co uk ...

Reviews: