Page 1: ...POE084824B v 1 0 PoE 54V 8x0 3A 4x7Ah PoE buffer power supply for up to 8 IP camera EN Edition 4 from 25 05 2015 Supersedes the edition 3 from 15 05 2014 GREEN POWER CCTV PoE...

Page 2: ...D optical indication protections SCP short circuit protection OVP overvoltage protection Surge protection Antisabotage protection OLP overload protection Mounting plate for mounting the network switch...

Page 3: ...et network standard are not used for data transmission data transmission uses 1 2 and 3 6 data pairs The PSU can not be used in Gigabit Ethernet networks where all twisted pairs are involved in the tr...

Page 4: ...ble 1 The description of components of the PoE module Fig 2 Components arrangement Fig 3 The view of the PSU Component No Fig 3 Description 1 The module of the switch mode PSU 2 LED light indicating c...

Page 5: ...c current limiting Battery circuit protection SCP and reverse polarity connection melting fuse Overvoltage protection OVP 62 1 72 9V DC Deep discharge battery protection UVP U 37 V 5 disconnecting the...

Page 6: ...vironmental class with normal relative humidity RH 90 maximum no condensation and temperature range from 10 C up to 40 C The power supply should operate in a vertical position in order to provide free...

Page 7: ...nnected to the terminal marked with the symbol in the PSU enclosure Operation of the PSU without the properly made and fully operational shock protection circuit is UNACCEPTABLE It can cause damage to...

Page 8: ...LED Fig 2 component 1 indicates DC voltage at the PoE module input During normal operation DC supply the LED is permanently illuminated No DC no DC voltage at the module input is indicated by turning...

Page 9: ...If the PTC polymer fuses are used disconnect the load from the power supply output for approximately 1 minute to restore output voltage the time needed to cool down the PTC fuse In case of melting fus...

Page 10: ...service centre of the manufacturer 6 The repair period mentioned in point 5 may be prolonged if there are no technical possibilities to carry out the repairs or if the equipment has been conditionally...