AC Pilot Indicator Light

The green AC Pilot Indicator Light comes on when the engine starts
and generates power.

CONTROL PANEL FUNCTIONS

Oil Warning 

Indicator

light

Overload 

Indicator

light

AC Pilot 

Indicator

light

DC Circuit Breaker

When the DC Circuit Breaker is in the “ON” position, the generator is able to supply power to connected electronic devices. 
When the DC Circuit Breaker is in the “OFF” position, the generator will no longer supply power. The DC Circuit Breaker 
automatically turns “OFF” when connecting electronic devices to the generator that exceed the generator’s rated output. If 
the DC Circuit Breaker turns off, reduce the load of connected electronic devices until the load is within the specified rated 
output. To re-establish power, return the DC Circuit Breaker back to the “ON” position.

CAUTION!

If the DC   Circuit Breaker turns off again, stop using the generator immediately and consult a

qualified electrician or small Engine repair shop.

Engine 

Economy

 Control

When the Engine 

Economy

 switch is turned to the “ON” position, the economy control unit automatically determines the

generator’s proper engine speed based on the connected electronic load. This results in superior fuel economy and
reduces noise.

When the 

Economy

 switch is turned to the “OFF” position, the engine runs at the rated speed of 4,1 0 r/min.

Note:

 

The engine overload indicator light may turn on for a few sec-

onds when attaching a load due to a power surge.  This is normal.

Oil Warning 

Indicator

light

Overload 

Indicator

light

AC Pilot 

Indicator

light

Summary of Contents for G2319N

Page 1: ...ne support pulsar products com OPERATOR S MANUAL Model G2319N Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other re...

Page 2: ...em 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How to Stop Engine 14 Attaching Electronic Devices 14 Charging a 12 Volt Battery 15 AC Parall...

Page 3: ...4 5L 1 18Gal camping equipment lighting or serve as a back up power source during power outages Date of Purchase Model Number Serial Number The emissions control system for this generator is complian...

Page 4: ...esult in serious injury or death WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigu...

Page 5: ...slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the spark plug wire and make sure the fuel tank is empty with the 3 in...

Page 6: ...nerator electronic devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Use a...

Page 7: ...H Recoil Starter Q Parallel Outlets R Ground Terminal S Circuit Breaker T 12V DC Port U 12V DC 8A Circuit Breaker CH O KE O FF I Control Panel J Oil Warning Light K Overload Indicator Light L AC Pilot...

Page 8: ...ight If the engine overload indicator light comes on the generator s wattage amperage capacity has been exceeded by connected electrical devices or by a power surge When this occurs the green AC Pilot...

Page 9: ...devices until the load is within the specified rated output To re establish power return the DC Circuit Breaker back to the ON position CAUTION If the DC Circuit Breaker turns off again stop using th...

Page 10: ...ected ground faults Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to pre...

Page 11: ...very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System If connecting generator to a building s electrical system fo...

Page 12: ...ine Insert a funnel into the crankcase dipstick hole and carefully add the specified amount of 4 Cycle engine oil SAE 10W 30 to empty reservoir until or oil reaches the outer edge of the oil fill hole...

Page 13: ...he ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then gradually as engine w...

Page 14: ...he fuel cap Air Vent to the OFF position How to Attach Electronic Devices 1 Before Starting generator Make sure the generator is grounded see page 10 for instructions Make sure the attached load is wi...

Page 15: ...ur with a hydrometer to prevent overcharging and to test the battery s condition Be careful to follow the hydrometer manufacture s instruction Do not disconnect battery clamps while charging Batteries...

Page 16: ...ces that have a damaged cord or plug If an appliance begins to operate abnormally becomes sluggish or stalls turn off and disconnect appliance immediately The appliance may have a fault or its rated l...

Page 17: ...Washing Machine 1150 3400 Gas Clothes Dryer 700 2500 Wattage Reference Guide Wattages listed are just approximations Check electronic device for actual wattage Don t Overload Generator Make sure you...

Page 18: ...debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedure after each use Shut off engine Store unit in a clean and dry area W...

Page 19: ...k plug should be replaced annually Reconnect spark plug wire Replace spark plug cap then replace cap Standard Spark Plug E6TC E6RTC BPR7HS Spark Plug Gap 0 6 0 7mm 0 024 0 028 in Spark Plug Torque 20...

Page 20: ...tion At high altitude the standard carburetor air fuel mixture will be too rich Performance will decrease and fuel consumption will increase A very rich mixture will also foul the spark plug and cause...

Page 21: ...should be damp but not dripping Do not run the generator without reinstalling the foam element or excessive piston and cylinder wear may result CAUTION Remove screws then remove the muffler cover as...

Page 22: ...or must be Shipped Run and Stored in the upright position as seen For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system For long te...

Page 23: ...MAINTENANCE CH O K E O FF Remove the spark plug and pour about 1 teaspoon of 10W30 Engine oil into the spark plug hole Reinstall the spark plug With the 3 in 1 switch in the OFF position pull the rec...

Page 24: ...act service department 5 Contact service department Engine will not start shuts down during operation or starts and runs rough 1 3 in 1 switch set to OFF 2 Dirty Air filter 3 Clogged fuel filter 4 Out...

Page 25: ...placement cc 80 Fuel Type Unleaded Gasoline Fuel Tank Capacity 4 5L 1 18gal Continued Running Time At Rated Power 4 8hours Engine Oil Capacity 350ml 11 8oz Spark Plug Model No E6TC E6RTC 7 Starter T R...

Page 26: ...WIRING DIAGRAM 26 Gener at or 1 2 3 4...

Page 27: ...all generator components and labor Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including commercial constructio...

Page 28: ...on websites such as ebay are not covered under this warranty Products used for commercial use are not covered under this warranty How to Obtain Warranty Service Take the original receipt and product t...

Reviews: