Pulsar G2319N Operator'S Manual Download Page 8

8

CONTROL PANEL FUNCTIONS

ON/OFF Start Switch and Choke

Start Switch “OFF”
When the Start Switch is in the “OFF” position the fuel valve is 
switched off and the engine will not run.

Start Switch “CHOKE”
When the Start Switch is in the “CHOKE” position the fuel valve is 
switched on and the engine can be started.

Start Switch “R

U

N”

When the Start Switch is in the “R

U

N” position the fuel valve is 

switched on and the engine can run.

Note:

 

The Choke is not required to start a warm engine

Oil Warning Indicator Light

When the oil falls below the minimum level, the oil warning indicator 

light comes on and the engine stops automatically.  The engine will not 

Note:

 

If the oil warning indicator light does not come on and the 

engine stalls, turn the Start Switch to “R

U

N” and pull the recoil 

starter.

Engine Overload Indicator Light

If the engine overload indicator light comes on, the generator s wattage 
/ amperage capacity has been exceeded by connected electrical 
devices or by a power surge.   When this occurs, the green AC Pilot 
Indicator Light will go off.  The engine will continue to run, 

(

but the red 

Engine Overload Indicator Light will stay on and power will no longer be 
supplied to connected electronic devices.

)

Oil Warning 

Indicator

light

Overload 

Indicator

light

AC Pilot 

Indicator

light

CH O K E

O FF

,

start nutil the proper amount of oil is in the crank case.

USB Outlet

The Generator offers

 

convenient (5V DC 1.5A) USB outlet to allow

SB

GPS, Digital

Cameras and other USB chargable devices.

 devices like Tabelets, MP3 players, 

How to Correct

1. Disconnect any electronic devices then stop the engine.
2. Reduce the total wattage of  connected electronic devices until it is

within the generator’s rated output.

3. Inspect the Air Inlet and Control Panel for any blockage.  Remove

blockage if found.

4. Restart Engine.

charging of U

R

UN

U

SB

Summary of Contents for G2319N

Page 1: ...ne support pulsar products com OPERATOR S MANUAL Model G2319N Warning The Engine Exhaust from this product contains chemicals known to the State of California to cause cancer birth defects or other re...

Page 2: ...em 11 Adding Fuel 11 Adding Checking Oil 12 Operation 13 Grounding the Generator 13 How to Start Engine 13 How to Stop Engine 14 Attaching Electronic Devices 14 Charging a 12 Volt Battery 15 AC Parall...

Page 3: ...4 5L 1 18Gal camping equipment lighting or serve as a back up power source during power outages Date of Purchase Model Number Serial Number The emissions control system for this generator is complian...

Page 4: ...esult in serious injury or death WARNING Safety Instructions Using a generator indoors WILL KILL YOU IN MINUTES Carbon monoxide gas is a poisonous odorless gas that can cause headache confusion fatigu...

Page 5: ...slowly To keep fuel from spilling secure unit so it cannot tip while operating or transporting When transporting unit disconnect the spark plug wire and make sure the fuel tank is empty with the 3 in...

Page 6: ...nerator electronic devices or any cord while standing in water while barefoot or when hands or feet are wet Always keep the generator dry Never operate generator in rain or under wet conditions Use a...

Page 7: ...H Recoil Starter Q Parallel Outlets R Ground Terminal S Circuit Breaker T 12V DC Port U 12V DC 8A Circuit Breaker CH O KE O FF I Control Panel J Oil Warning Light K Overload Indicator Light L AC Pilot...

Page 8: ...ight If the engine overload indicator light comes on the generator s wattage amperage capacity has been exceeded by connected electrical devices or by a power surge When this occurs the green AC Pilot...

Page 9: ...devices until the load is within the specified rated output To re establish power return the DC Circuit Breaker back to the ON position CAUTION If the DC Circuit Breaker turns off again stop using th...

Page 10: ...ected ground faults Only operate generator on a level surface Always connect the nut and ground terminal on the frame to an appropriate ground source WARNING Generator must be properly grounded to pre...

Page 11: ...very high voltage which could result in burn or electrocution causing serious injury or death Connecting Generator to an Electrical System If connecting generator to a building s electrical system fo...

Page 12: ...ine Insert a funnel into the crankcase dipstick hole and carefully add the specified amount of 4 Cycle engine oil SAE 10W 30 to empty reservoir until or oil reaches the outer edge of the oil fill hole...

Page 13: ...he ON position Turn the 3 in 1 Start Switch to CHOKE Pull recoil handle starter cord slowly until resistance is felt then pull rapidly Let engine run for several seconds and then gradually as engine w...

Page 14: ...he fuel cap Air Vent to the OFF position How to Attach Electronic Devices 1 Before Starting generator Make sure the generator is grounded see page 10 for instructions Make sure the attached load is wi...

Page 15: ...ur with a hydrometer to prevent overcharging and to test the battery s condition Be careful to follow the hydrometer manufacture s instruction Do not disconnect battery clamps while charging Batteries...

Page 16: ...ces that have a damaged cord or plug If an appliance begins to operate abnormally becomes sluggish or stalls turn off and disconnect appliance immediately The appliance may have a fault or its rated l...

Page 17: ...Washing Machine 1150 3400 Gas Clothes Dryer 700 2500 Wattage Reference Guide Wattages listed are just approximations Check electronic device for actual wattage Don t Overload Generator Make sure you...

Page 18: ...debris If dirt is caked on use a soft bristle brush Inspect the work area for hazards After Each Use Follow the following procedure after each use Shut off engine Store unit in a clean and dry area W...

Page 19: ...k plug should be replaced annually Reconnect spark plug wire Replace spark plug cap then replace cap Standard Spark Plug E6TC E6RTC BPR7HS Spark Plug Gap 0 6 0 7mm 0 024 0 028 in Spark Plug Torque 20...

Page 20: ...tion At high altitude the standard carburetor air fuel mixture will be too rich Performance will decrease and fuel consumption will increase A very rich mixture will also foul the spark plug and cause...

Page 21: ...should be damp but not dripping Do not run the generator without reinstalling the foam element or excessive piston and cylinder wear may result CAUTION Remove screws then remove the muffler cover as...

Page 22: ...or must be Shipped Run and Stored in the upright position as seen For semi long term storage add fuel stabilizer to prevent stale fuel from causing acid and gum deposits in the fuel system For long te...

Page 23: ...MAINTENANCE CH O K E O FF Remove the spark plug and pour about 1 teaspoon of 10W30 Engine oil into the spark plug hole Reinstall the spark plug With the 3 in 1 switch in the OFF position pull the rec...

Page 24: ...act service department 5 Contact service department Engine will not start shuts down during operation or starts and runs rough 1 3 in 1 switch set to OFF 2 Dirty Air filter 3 Clogged fuel filter 4 Out...

Page 25: ...placement cc 80 Fuel Type Unleaded Gasoline Fuel Tank Capacity 4 5L 1 18gal Continued Running Time At Rated Power 4 8hours Engine Oil Capacity 350ml 11 8oz Spark Plug Model No E6TC E6RTC 7 Starter T R...

Page 26: ...WIRING DIAGRAM 26 Gener at or 1 2 3 4...

Page 27: ...all generator components and labor Personal use means personal residential household use or recreational use by the retail consumer Commercial use means all other uses including commercial constructio...

Page 28: ...on websites such as ebay are not covered under this warranty Products used for commercial use are not covered under this warranty How to Obtain Warranty Service Take the original receipt and product t...

Reviews: