FLOWPULSE INSTRUCTION MANUAL
18
•
Ensure that both the base of the FlowPulse and the pipe surface are
free from debris. Pipes with flaking paint should be cleaned down.
•
Apply silicone grease or silicone pad to the base of Flow Pulse.
Silicone pad is recommended where vibration and heat are
frequently encountered.
•
FlowPulse should be strapped onto the pipe with the supplied metal
banding. If further installation attempts are made, reapply silicone
grease. In the case of silicone pad, ensure that the pad surface is
clean from debris, the pad is in good condition, and there is no
folding that might cause uneven contact with the pipe.
•
Ensure that the FlowPulse is aligned along the pipe axis, as
illustrated in Figure 3:
Figure 3: Flow Pulse correctly aligned along the pipe axis.
•
Tighten the banding while ensuring best contact and correct
alignment between the Flow Pulse and the pipe.
Flow Pulse PC Installation
The FlowPulse PC software is supported on Win 7, Win 8 and Win 10 (32 and
64 bit). The .Net Framework 4.0 is required to run the program. This is free
for download online.
Run Setup.exe if downloaded from the Pulsar website
(
https://www.pulsarmeasurement.com
) to install the FlowPulse PC software.
Or alternatively, if you are installing from the CD provided please select to
install FlowPulse PC software from the options on screen. A FlowPulse PC
shortcut icon will then be created on the Desktop. Double click on the
shortcut icon to launch the program.
FlowPulse
FlowP