![Pulsar blackbox 130 Instruction Manual Download Page 86](http://html1.mh-extra.com/html/pulsar/blackbox-130/blackbox-130_instruction-manual_1624510086.webp)
Page
80
The choices for you to enter are as follows.
1= Manual soft simulation
2= Automatic soft simulation
3= Manual hard simulation
4= Automatic hard simulation
To return to program mode, press
CANCEL
and test mode will end.
P981 Increment
By default, simulation mode will move by
0.328 feet
steps in manual
simulation and by 0.328 feet/min in automatic simulation. Altering the
increment can change this value.
P982 Rate
In automatic mode, the rate at which the level will move up and down is
determined by distance,
P981 Increment
and the time,
P982 Rate
which can
be changed as required. To increase the rate at which the level moves increase
the
Increment (P981)
or decrease the
Rate (P982)
. To decrease the rate at
which the level moves decrease the
Increment (P981)
or increase the
Rate
(P982)
.
Hardware
P990 Self Test
If you enter 1 for this parameter, then the unit will perform a self-test. This
will confirm that the various parts of the circuitry are working correctly. You
will see confirmation messages that the clock and the EEPROM are working
correctly, and error messages for any parts that fail.
P991 Hard Test
Dependant on model type, when this parameter is selected, the unit will test
the following in turn.
*
LED’s
. Watch them change colour as shown on the display, and
press,
ENTER,
if they operated as shown.
*
Relays
. Press a numeric key corresponding to the number of the
relay you wish to test, and the relay will change state each time the
key is pressed. If you press any other key, other than a valid relay
number, then the test will end.
*
Segments
. All the segments on the LCD are lit up, so you can see if
they all work. Press,
ENTER,
to end the test. The LED’s all go green
at the same time.