Possible cause
You are looking through glass.
Solution
Remove the glass or change the viewing position to avoid it.
☐
Poor image quality / Detection range reduced
Possible cause
These problems may occur during observation in adverse weather conditions (snow, rain,
fog, etc.).
☐
The image quality during the device operation at below
zero temperatures is worse than at positive temperatures
Possible cause
In positive temperature conditions, objects being observed (surroundings and
background) heat up differently because of thermal conductivity, thereby generating a
high temperature contrast. Consequently, the image quality produced by the thermal
imager will be better.
In low-temperature conditions, objects being observed (background) will cool down to
roughly the same temperature, which leads to a greatly reduced temperature contrast and
a degraded image quality. This is normal for all thermal imaging devices.
☐
Rangefinder does not measure distance
Possible cause
There is an object in front of the receiver or emitter lens preventing signal transmission.
Solution
Make sure that: the lenses are not blocked by your hand or fingers; the lenses are clean.
Possible cause
The device is not being held steadily when measuring.