12
Figure 11
Remove the unattached coupling half from the motor adaptor. Ensure that the elastomer
coupling spider remains in place, on the coupling half that remains attached to the worm
shaft.
If applicable, remove any tape or retainer rings that hold the motor shaft key in place.
Place the loose coupling half on the motor shaft. Align the keyway with the key and
align shaft end to inner coupling surface as shown in figure above.
Tighten the setscrew onto the shaft key.
Place the motor in a vertical position and align the coupling teeth.
Install the motor downwards onto the adaptor. The plastic guide will assist in aligning
the coupling halves. Final position can be achieved by slightly rotating the motor until
the coupling jaws align.
Rotate the motor until the clearance holes in the adaptor and the tapped holes in the
motor align. Fasten the motor to the adaptor using the supplied bolts (4). Tighten bolts
evenly to secure motor.
4.7.3 Electrical
Wire the PULSAR Shadow® drive motor according to the motor vendor’s nameplates
and instructions, and according to any appropriate national and local electrical codes
and regulations.
If the motor is to be utilized with a Pulsafeeder controller, such as the DLC or DLCM,
consult the appropriate Pulsafeeder IOM for further motor wiring instructions.
5. Equipment Startup
PULSAR
S
HADOW
®
PUMP USE TWO SEPARATE OILS
:
P
ULSALUBE
9M
OIL FOR THE
ECCENTRIC BOX AND
P
ULSALUBE
8G,
GEAR OIL FOR THE GEARBOX
.
C
ONFUSION
BETWEEN THE TWO REDUCES PERFORMANCE OF THE PUMP
.