Connect a vacuum pump to the top fitting of the fluid fill device. Open BOTH
valves on the device.
•
Place the lower fill tube into the container of the barrier fluid
•
Using the vacuum function, use the hand pump to draw several ounces of fluid up
into the fill device.
•
Close both valves on the fill device
•
Remove the hose and fitting from the container, and connect the fluid fill device to
the inlet fitting on the pump head (the fitting with the needle valve).
•
Open the fill valve (needle valve) on the pump, and then open the two plastic
valves on the fluid fill device.
•
Switch the hand pump to the pressure function, and apply a maximum of 15 psi of
pressure to the fluid in the chamber. Once pressure is achieved, close the TOP
valve and disconnect the hand pump. There is now pressure pushing the barrier
fluid into the leak detection system.
•
Move the hand pump to the outlet side of the system, switch it to the vacuum
function, and continue with the filling process as outlined in the main document.