13
7.0 Setup for Pressure
Pumps incorporating pressure leak detection are shipped from the factory with the
system fully set up to work at full pump pressure. No further setup is required. The
standard factory barrier fluid is silicone oil, if any other customer-specified media is
used it must be compatible with construction materials. The system will require proper
setup after maintenance or repairs see the following page for the proper procedure.
Figure 5 – pressure system
THE BARRIER FLUID USED TO PRIME THE SYSTEM WILL VARY WITH THE
APPLICATION. THE FLUID SELECTED MUST BE COMPATIBLE WITH THE
MATERIALS OF CONSTRUCTION USED IN THE DIAPHRAGM AND DETECTION
ASSEMBLY. IT SHOULD ALSO BE COMPATIBLE WITH THE PROCESS FLUID
AND THE PROCESS CONDITIONS