27
DIFFICULTY
PROBABLE CAUSE
REMEDY
Delivery erratic
Leak in suction line
Locate and correct
Product cavitating
Increase suction pressure
Entrained air or gas in product
Consult factory for suggested venting
Motor speed erratic
Check voltage and frequency
Fouled check valves
Clean, replace if necessary
Inadequate backpressure
Increase discharge pressure to obtain a
minimum pressure difference of 5 psi from
suction to discharge
Delivery higher than rated
Suction pressure higher than discharge
pressure
Install backpressure valve or consult
factory for piping recommendations
Back pressure valve set too low
Increase setting
Vack pressure valve leaks
Repair, clean or replace
Noisy gearing, knocking
Discharge pressure too high
Reduce pressure
Water hammer
Install pulsation dampener
Low oil level
Examine sight glass on side of pump, add or
replace oil as required.
Piping noisy
Pipe size too small
Increase size of piping - install pulsation
dampener
Pip runs too long
Install pulsation dampener in line
Pulsation sampener inoperative or flooded
Refill with air or insert gas. Inspect and replace
diaphragm and recharge
No surge chamber or dampener used
Install pulsation dampener
Motor overheats
Pump overloaded
Check operating conditions against pump
design. Verify discharge pressure
High or low voltage
Check power source
Loose wire
Trace and correct
Incorrect motor wiring
Verify and correct
Oil level low
Check and add as necessary
Summary of Contents for PULSA GLM7