ML60.241
MiniLine-2
24V,
2.5A,
S
INGLE
P
HASE
I
NPUT
5.
O
UTPUT
Output voltage
nom.
24V
Adjustment range
min.
24-28V
guaranteed
max.
30V *)
at clockwise end position of potentiometer
Factory setting
24.5V
±0.2%, at full load, cold unit
Line regulation
max.
10mV
85-264Vac
Load regulation
max.
100mV
static value, 0A
Æ
2.5A
Ripple and noise voltage
max.
50mVpp
20Hz to 20MHz, 50Ohm
Output capacitance
typ.
1 600μF
Output current
nom.
2.5A
at 24V, see Fig. 5-1
nom.
2.1A
at 28V, see Fig. 5-1
Output power
nom.
60W
Short-circuit current
min.
3.6A
load impedance 400mOhm, see Fig. 5-1
max.
6.2A
load impedance 400mOhm, see Fig. 5-1
*)
This is the maximum output voltage which can occur at the clockwise end position of the potentiometer due to tolerances. It is not
guaranteed value which can be achieved. The typical value is about 28.6V.
Fig. 5-1
Output voltage vs. output current,
typ.
Output Voltage
0
0
4
8
12
28V
16
20
24
3
2
1
5
6A
4
Adjustment
Range
Output Current
a) 100Vac
b) 120Vac
c) 230Vac
b
c
a
Peak current capability (up to several milliseconds)
The power supply can deliver a peak current which is higher than the specified short term current. This helps to start
current demanding loads or to safely operate subsequent circuit breakers.
The extra current is supplied by the output capacitors inside the power supply. During this event, the capacitors will be
discharged and causes a voltage dip on the output. Detailed curves can be found in chapter 22.1.
Peak current voltage dips
typ.
from 24V to 16V
at 5A for 50ms, resistive load
typ.
from 24V to 15V
at 12.5A for 2ms, resistive load
typ.
from 24V to 10.5V
at 12.5A for 5ms, resistive load
Nov. 2015 / Rev. 1.4 DS-ML60.241-EN
All parameters are specified at 24V, 2.5A, 230Vac 50Hz input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
6/23