FPS300.245-049-102
All parameters are specified at 24 V, 12.5 A, 230 Vac, 25 °C ambient and after a 5 minutes run-in time unless otherwise noted.
Apr. 2022 / Rev. 0.2 FPS300-EN
19 / 28
EMC Emission
Conducted emission AC input lines
EN 55011, EN 55015, EN 55032,
FCC Part 15, CISPR 11, CISPR 32
Class B
Conducted emission DC output lines IEC/CISPR 16-1-2, IEC/CISPR 16-2-1
Conducted emission Out-OK output
Radiated emission
EN 55032 / EN 55011
Class B
Harmonics
EN 61000-3-2
Class A fulfilled between 0A and 12A load
Voltage fluctuations, flicker
EN 61000-3-3
Pass tested with constant current loads, non
pulsing
This device complies with FCC Part 15 rules.
Operation is subjected to following two conditions: (1) this device may not cause harmful interference, and (2) this
device must accept any interference received, including interference that may cause undesired operation.
Switching Frequencies
PFC converter
20 kHz to 135 kHz
Input voltage and output load dependent
Main converter
60 kHz to 140 kHz
Output load dependent
Auxiliary converter
54 kHz to 66 kHz
Output load dependent
Microcontroller clocks
48 Mhz and 32 MHz
Fixed frequency