To change the batteries:
1. Unscrew the 2 6-32 x
½
” phillips
head machine screws which hold
the battery cover in place.
2. While holding the leads in one hand,
gently disconnect the batteries from
the leads. Be careful not to tear the
leads off the wires or the tear the
lead wires out of the power supply.
3. Connect 2 fresh 9 volt batteries to
the leads.
4. Replace the battery cover. Screw
the 2 6-32 x
½
” Phillips head
machine screws back in to secure
the battery cover.
The Batteries
The nozzle charging operates on two 9 volt
rechargeable batteries which are located in
the base of the handgun. In average
conditions, the batteries will last 5-10 hours
of operation on a charge. They should be
recharged when the charging indicator on
top of the handgun shell doesn’t glow when
the trigger is engaged during operation.
After a while the batteries will wear out and
need to be changed. Replace with Nickel-
Hydride rechargeable batteries.