Problem solving
I940T/I2000T is designed and manufactured for a severe environment and tasks, but the user must
note that the machine components must be protected from knocks and blows. Filter, seals,
attachments, and connections are carefully adapted and selected with regard to the operator’s work
environment. Therefore, the operator and service personnel must treat the machine with care if it is to
work correctly for many years.
Problem
Cause
Procedure
Ejector doesn´t start
Low feed pressure
Bigger Compressor
Ejector runs, but no suction Hose not connected
Connect the hose
Hose blocked
Clean the hose
Ejector works, but
Hole on the hose
Change hose
poor suction
Blocked filter
Change filter
Suction unit loose
Adjust
Dirt in the hose or
Clean the hose and intake
intake
Defect sealings
Change current sealing
Dust is blowing from motor Defect or loose filter
Adjust or change
Abnormal noise
Order service
KEEP THESE INSTRUCTIONS!