-Cable connection at Secondary Node panels (cont.).
•
Incoming Serial Data cable will plug into the CN1 port on the Secondary Node panel.
•
The CN2 port is reserved for out going signal to additional node panels or the
Termination Resistor for the last node panel.
Figure 8
Termination Resistor
NOTE: For safe and reliable communication between the system components it is imperative
that the interconnected wiring be installed correctly and according to these instructions.
Failure to do this can result in an inoperative system, sluggish response, or inability to
reliably control the system components.
NOTE:
Do not run communications cable through conduits or junction boxes with any other
wires except the low voltage wires between TSC system components. Do not run low
voltage wires through conduits or junction boxes containing any of the 120v motor wires
from the field devices such as backstops or curtains.
NOTE:
Make note of wire color attached to each terminal. This may vary depending on brand
of twisted pair shielded cable in use.